{"global":{"lastError":{},"locale":"de","locales":{"data":[{"id":"de","name":"Deutsch"},{"id":"en","name":"English"}],"loading":false,"error":false},"currency":{"id":49,"name":"EUR"},"currencies":{"data":[{"id":49,"name":"EUR"},{"id":124,"name":"RUB"},{"id":153,"name":"UAH"},{"id":155,"name":"USD"}],"loading":false,"error":false},"translations":{"implementations":{"categories":{"_type":"localeString","en":"Categories","ru":"Категории"},"more":{"ru":"Узнать больше","_type":"localeString","en":"Learn more"},"sort-title-asc":{"ru":"От А до Я","_type":"localeString","en":"From A to Z"},"sort-title-desc":{"_type":"localeString","en":"From Z to A","ru":"от Я до А"},"sort-rating-asc":{"ru":"По возрастанию рейтинга","_type":"localeString","en":"Rating ascending"},"sort-rating-desc":{"ru":"По убыванию рейтинга","_type":"localeString","en":"Rating descending"},"sort-discount-asc":{"en":"Rebate ascending","ru":"По возрастанию скидки","_type":"localeString"},"sort-discount-desc":{"ru":"По убыванию скидки","_type":"localeString","en":"Rebate descending"},"user":{"_type":"localeString","en":"User","ru":"Пользователь"},"vendor":{"en":"Vendor","ru":"Производитель","_type":"localeString"},"supplier":{"ru":"Поставщик","_type":"localeString","en":"Supplier"},"status":{"_type":"localeString","en":"Status","ru":"Статус"},"product":{"_type":"localeString","en":"Product","ru":"Продукт"},"no-results":{"en":"No results found. We didn't find any results with the filter you selected.","ru":"По вашему запросу ничего не найдено, попробуйте изменить запрос.","_type":"localeString"},"with-reference":{"ru":"С референсом","_type":"localeString","en":"With reference"},"items-found":{"ru":"Внедрений найдено","_type":"localeString","en":"Deployments found"},"canceled":{"ru":"Отменено","_type":"localeString","en":"Canceled"},"deal-canceled":{"_type":"localeString","en":"Deal canceled","ru":"Сделка отменена"},"deal-closed":{"ru":"Сделка закрыта","_type":"localeString","en":"Deal closed"},"deal-in-progress":{"en":"Deal in progress","ru":"Сделка в процессе","_type":"localeString"},"deal-is-planned":{"en":"Deal is planned","ru":"Сделка планируется","_type":"localeString"},"finished":{"en":"Finished","ru":"Завершено","_type":"localeString"},"in-process":{"ru":"Ведется","_type":"localeString","en":"In Process"},"planned":{"en":"Planned","ru":"Планируется","_type":"localeString"},"proof-of-concept":{"ru":"Пилотный проект","_type":"localeString","en":"Proof of concept"},"stopped":{"_type":"localeString","en":"Stopped","ru":"Остановлено"},"date":{"ru":"Дата внедрения","_type":"localeString","en":"Deployment date"},"roi":{"_type":"localeString","en":"ROI","ru":"ROI"},"implementations-fetching-error":{"ru":"Произошла ошибка. Перезагрузите пожалуйста страницу.","_type":"localeString","en":"An error has occurred. Please reload the page."}},"header":{"help":{"_type":"localeString","en":"Help","de":"Hilfe","ru":"Помощь"},"how":{"_type":"localeString","en":"How does it works","de":"Wie funktioniert es","ru":"Как это работает"},"login":{"de":"Einloggen","ru":"Вход","_type":"localeString","en":"Log in"},"logout":{"_type":"localeString","en":"Sign out","ru":"Выйти"},"faq":{"en":"FAQ","de":"FAQ","ru":"FAQ","_type":"localeString"},"references":{"de":"References","ru":"Мои запросы","_type":"localeString","en":"Requests"},"solutions":{"en":"Solutions","ru":"Возможности","_type":"localeString"},"find-it-product":{"_type":"localeString","en":"Selection and comparison of IT product","ru":"Подбор и сравнение ИТ продукта"},"autoconfigurator":{"ru":"Калькулятор цены","_type":"localeString","en":" Price calculator"},"comparison-matrix":{"en":"Comparison Matrix","ru":"Матрица сравнения","_type":"localeString"},"roi-calculators":{"ru":"ROI калькуляторы","_type":"localeString","en":"ROI calculators"},"b4r":{"en":"Bonus for reference","ru":"Бонус за референс","_type":"localeString"},"business-booster":{"_type":"localeString","en":"Business boosting","ru":"Развитие бизнеса"},"catalogs":{"ru":"Каталоги","_type":"localeString","en":"Catalogs"},"products":{"ru":"Продукты","_type":"localeString","en":"Products"},"implementations":{"ru":"Внедрения","_type":"localeString","en":"Deployments"},"companies":{"_type":"localeString","en":"Companies","ru":"Компании"},"categories":{"en":"Categories","ru":"Категории","_type":"localeString"},"for-suppliers":{"en":"For suppliers","ru":"Поставщикам","_type":"localeString"},"blog":{"en":"Blog","ru":"Блог","_type":"localeString"},"agreements":{"en":"Deals","ru":"Сделки","_type":"localeString"},"my-account":{"en":"My account","ru":"Мой кабинет","_type":"localeString"},"register":{"ru":"Зарегистрироваться","_type":"localeString","en":"Register"},"comparison-deletion":{"_type":"localeString","en":"Deletion","ru":"Удаление"},"comparison-confirm":{"ru":"Подтвердите удаление","_type":"localeString","en":"Are you sure you want to delete"},"search-placeholder":{"ru":"Введите поисковый запрос","_type":"localeString","en":"Enter your search term"},"my-profile":{"ru":"Мои данные","_type":"localeString","en":"My profile"},"about":{"_type":"localeString","en":"About Us"},"it_catalogs":{"_type":"localeString","en":"IT catalogs"},"roi4presenter":{"_type":"localeString","en":"Roi4Presenter"},"roi4webinar":{"_type":"localeString","en":"Pitch Avatar"},"sub_it_catalogs":{"en":"Find IT product","_type":"localeString"},"sub_b4reference":{"en":"Get reference from user","_type":"localeString"},"sub_roi4presenter":{"_type":"localeString","en":"Make online presentations"},"sub_roi4webinar":{"_type":"localeString","en":"Create an avatar for the event"},"catalogs_new":{"en":"Products","_type":"localeString"},"b4reference":{"_type":"localeString","en":"Bonus4Reference"},"it_our_it_catalogs":{"_type":"localeString","en":"Our IT Catalogs"},"it_products":{"_type":"localeString","en":"Find and compare IT products"},"it_implementations":{"_type":"localeString","en":"Learn implementation reviews"},"it_companies":{"_type":"localeString","en":"Find vendor and company-supplier"},"it_categories":{"_type":"localeString","en":"Explore IT products by category"},"it_our_products":{"_type":"localeString","en":"Our Products"},"it_it_catalogs":{"_type":"localeString","en":"IT catalogs"}},"footer":{"copyright":{"_type":"localeString","en":"All rights reserved","de":"Alle rechte vorbehalten","ru":"Все права защищены"},"company":{"_type":"localeString","en":"My Company","de":"Über die Firma","ru":"О компании"},"about":{"de":"Über uns","ru":"О нас","_type":"localeString","en":"About us"},"infocenter":{"en":"Infocenter","de":"Infocenter","ru":"Инфоцентр","_type":"localeString"},"tariffs":{"de":"Tarife","ru":"Тарифы","_type":"localeString","en":"Subscriptions"},"contact":{"de":"Kontaktiere uns","ru":"Связаться с нами","_type":"localeString","en":"Contact us"},"marketplace":{"ru":"Marketplace","_type":"localeString","en":"Marketplace","de":"Marketplace"},"products":{"en":"Products","de":"Produkte","ru":"Продукты","_type":"localeString"},"compare":{"_type":"localeString","en":"Pick and compare","de":"Wähle und vergleiche","ru":"Подобрать и сравнить"},"calculate":{"de":"Kosten berechnen","ru":"Расчитать стоимость","_type":"localeString","en":"Calculate the cost"},"get_bonus":{"de":"Holen Sie sich einen Rabatt","ru":"Бонус за референс","_type":"localeString","en":"Bonus for reference"},"salestools":{"de":"Salestools","ru":"Salestools","_type":"localeString","en":"Salestools"},"automatization":{"en":"Settlement Automation","de":"Abwicklungsautomatisierung","ru":"Автоматизация расчетов","_type":"localeString"},"roi_calcs":{"en":"ROI calculators","de":"ROI-Rechner","ru":"ROI калькуляторы","_type":"localeString"},"matrix":{"en":"Comparison matrix","de":"Vergleichsmatrix","ru":"Матрица сравнения","_type":"localeString"},"b4r":{"de":"Rebate 4 Reference","ru":"Rebate 4 Reference","_type":"localeString","en":"Rebate 4 Reference"},"our_social":{"ru":"Наши социальные сети","_type":"localeString","en":"Our social networks","de":"Unsere sozialen Netzwerke"},"subscribe":{"de":"Melden Sie sich für den Newsletter an","ru":"Подпишитесь на рассылку","_type":"localeString","en":"Subscribe to newsletter"},"subscribe_info":{"_type":"localeString","en":"and be the first to know about promotions, new features and recent software reviews","ru":"и узнавайте первыми об акциях, новых возможностях и свежих обзорах софта"},"policy":{"en":"Privacy Policy","ru":"Политика конфиденциальности","_type":"localeString"},"user_agreement":{"ru":"Пользовательское соглашение ","_type":"localeString","en":"Agreement"},"solutions":{"ru":"Возможности","_type":"localeString","en":"Solutions"},"find":{"en":"Selection and comparison of IT product","ru":"Подбор и сравнение ИТ продукта","_type":"localeString"},"quote":{"_type":"localeString","en":"Price calculator","ru":"Калькулятор цены"},"boosting":{"en":"Business boosting","ru":"Развитие бизнеса","_type":"localeString"},"4vendors":{"en":"4 vendors","ru":"поставщикам","_type":"localeString"},"blog":{"ru":"блог","_type":"localeString","en":"blog"},"pay4content":{"en":"we pay for content","ru":"платим за контент","_type":"localeString"},"categories":{"ru":"категории","_type":"localeString","en":"categories"},"showForm":{"ru":"Показать форму","_type":"localeString","en":"Show form"},"subscribe__title":{"en":"We send a digest of actual news from the IT world once in a month!","ru":"Раз в месяц мы отправляем дайджест актуальных новостей ИТ мира!","_type":"localeString"},"subscribe__email-label":{"ru":"Email","_type":"localeString","en":"Email"},"subscribe__name-label":{"ru":"Имя","_type":"localeString","en":"Name"},"subscribe__required-message":{"ru":"Это поле обязательное","_type":"localeString","en":"This field is required"},"subscribe__notify-label":{"_type":"localeString","en":"Yes, please, notify me about news, events and propositions","ru":"Да, пожалуйста уведомляйте меня о новостях, событиях и предложениях"},"subscribe__agree-label":{"_type":"localeString","en":"By subscribing to the newsletter, you agree to the %TERMS% and %POLICY% and agree to the use of cookies and the transfer of your personal data","ru":"Подписываясь на рассылку, вы соглашаетесь с %TERMS% и %POLICY% и даете согласие на использование файлов cookie и передачу своих персональных данных*"},"subscribe__submit-label":{"ru":"Подписаться","_type":"localeString","en":"Subscribe"},"subscribe__email-message":{"en":"Please, enter the valid email","ru":"Пожалуйста, введите корректный адрес электронной почты","_type":"localeString"},"subscribe__email-placeholder":{"ru":"username@gmail.com","_type":"localeString","en":"username@gmail.com"},"subscribe__name-placeholder":{"ru":"Имя Фамилия","_type":"localeString","en":"Last, first name"},"subscribe__success":{"ru":"Вы успешно подписаны на рассылку. Проверьте свой почтовый ящик.","_type":"localeString","en":"You are successfully subscribed! Check you mailbox."},"subscribe__error":{"ru":"Не удалось оформить подписку. Пожалуйста, попробуйте позднее.","_type":"localeString","en":"Subscription is unsuccessful. Please, try again later."},"roi4presenter":{"en":"Roi4Presenter","de":"roi4presenter","ru":"roi4presenter","_type":"localeString"},"it_catalogs":{"_type":"localeString","en":"IT catalogs"},"roi4webinar":{"_type":"localeString","en":"Pitch Avatar"},"b4reference":{"_type":"localeString","en":"Bonus4Reference"}},"breadcrumbs":{"home":{"ru":"Главная","_type":"localeString","en":"Home"},"companies":{"ru":"Компании","_type":"localeString","en":"Companies"},"products":{"en":"Products","ru":"Продукты","_type":"localeString"},"implementations":{"en":"Deployments","ru":"Внедрения","_type":"localeString"},"login":{"ru":"Вход","_type":"localeString","en":"Login"},"registration":{"_type":"localeString","en":"Registration","ru":"Регистрация"},"b2b-platform":{"ru":"Портал для покупателей, поставщиков и производителей ИТ","_type":"localeString","en":"B2B platform for IT buyers, vendors and suppliers"}},"comment-form":{"title":{"_type":"localeString","en":"Leave comment","ru":"Оставить комментарий"},"firstname":{"ru":"Имя","_type":"localeString","en":"First name"},"lastname":{"ru":"Фамилия","_type":"localeString","en":"Last name"},"company":{"ru":"Компания","_type":"localeString","en":"Company name"},"position":{"_type":"localeString","en":"Position","ru":"Должность"},"actual-cost":{"ru":"Фактическая стоимость","_type":"localeString","en":"Actual cost"},"received-roi":{"ru":"Полученный ROI","_type":"localeString","en":"Received ROI"},"saving-type":{"_type":"localeString","en":"Saving type","ru":"Тип экономии"},"comment":{"en":"Comment","ru":"Комментарий","_type":"localeString"},"your-rate":{"_type":"localeString","en":"Your rate","ru":"Ваша оценка"},"i-agree":{"_type":"localeString","en":"I agree","ru":"Я согласен"},"terms-of-use":{"_type":"localeString","en":"With user agreement and privacy policy","ru":"С пользовательским соглашением и политикой конфиденциальности"},"send":{"ru":"Отправить","_type":"localeString","en":"Send"},"required-message":{"en":"{NAME} is required filed","ru":"{NAME} - это обязательное поле","_type":"localeString"}},"maintenance":{"title":{"ru":"На сайте проводятся технические работы","_type":"localeString","en":"Site under maintenance"},"message":{"en":"Thank you for your understanding","ru":"Спасибо за ваше понимание","_type":"localeString"}},"filters":{"from":{"_type":"localeString","en":"from","ru":"от"},"to":{"en":"to","ru":"до","_type":"localeString"},"filter-price-title":{"_type":"localeString","en":"Filter by price","ru":"Фильтр по цене"},"view-type-label":{"ru":"Вид","_type":"localeString","en":"View"},"sort-type-label":{"_type":"localeString","en":"Sorting","ru":"Сортировка"},"category":{"ru":"Категория","_type":"localeString","en":"Category"},"follow":{"ru":"Следить","_type":"localeString","en":"Follow"},"add-product":{"ru":"Добавить продукт","_type":"localeString","en":"Add Product"},"show-all":{"ru":"Показать все","_type":"localeString","en":"Show all"},"filter-toggle":{"en":"Filter","ru":"Фильтр","_type":"localeString"},"clear-button":{"en":"Сlear","ru":"Очистить","_type":"localeString"},"delivery-type-field":{"ru":"Тип поставки","_type":"localeString","en":"Delivery type"},"product-categories-field":{"ru":"категориz продуктаhjle","_type":"localeString","en":"product categories"},"providers-field":{"en":"Providers","ru":"Поставщик, производитель","_type":"localeString"},"business-tasks-field":{"ru":"Бизнес задачи","_type":"localeString","en":"Business tasks"},"problems-field":{"ru":"Проблемы","_type":"localeString","en":"Problems"},"with-discounts-checkbox":{"ru":"Со скидками","_type":"localeString","en":"With discounts"},"expert-price-checkbox":{"ru":"Конфигуратор","_type":"localeString","en":"Configurator"},"roi-calculator-checkbox":{"ru":"ROI-калькулятор","_type":"localeString","en":"ROI-calculator"},"apply-filter-button":{"ru":"Применить фильтр","_type":"localeString","en":"Apply filter"},"sorting-toggle":{"en":"Sorting","ru":"Сортировка","_type":"localeString"},"show-all-button":{"ru":"Показать все","_type":"localeString","en":"Show all"},"suggest-product-button":{"ru":"Предложить продукт","_type":"localeString","en":"Suggest product"},"with-projects-label":{"ru":"С внедрениями","_type":"localeString","en":"With deployments"},"bonus-4-reference":{"ru":"Бонус за референс","_type":"localeString","en":"Bonus 4 Reference"},"product-categories":{"ru":"Категории продуктов","_type":"localeString","en":"Product Categories"},"countries":{"_type":"localeString","en":"Countries","ru":"Страны"},"seller":{"en":"Seller","ru":"Продавец","_type":"localeString"},"vendors":{"ru":"Производители продуктов пользователя","_type":"localeString","en":"User products vendors"},"suppliers":{"ru":"Поставщики пользователя","_type":"localeString","en":"User suppliers"},"business-process":{"ru":"Проблемы","_type":"localeString","en":"Problems"},"business-objectives":{"ru":"Бизнес задачи","_type":"localeString","en":"Business tasks"},"branch":{"ru":"Отрасль","_type":"localeString","en":" Branch"},"users":{"ru":"Пользователи","_type":"localeString","en":"Users"},"status":{"en":"Status","ru":"Статус","_type":"localeString"},"info-source":{"ru":"Информационный ресурс","_type":"localeString","en":"Info source"},"with-reference-checkbox":{"ru":"С референсами","_type":"localeString","en":"With reference"},"show-deal-checkbox":{"ru":"Показывать сделки с noname","_type":"localeString","en":"Show deal with noname"},"roi-checkbox":{"en":"ROI","ru":"ROI","_type":"localeString"},"problems":{"en":"Problems","ru":"Проблемы","_type":"localeString"},"find":{"en":"Find","ru":"Выполнить поиск","_type":"localeString"},"deal-date":{"ru":"Дата","_type":"localeString","en":"Date"},"try-button":{"ru":"Попробовать AI (Beta)","_type":"localeString","en":"Try AI (Beta)"},"hide":{"_type":"localeString","en":"Hide","ru":"Скрыть"},"company-size":{"ru":"Размер компании","_type":"localeString","en":"Company size"},"add-company":{"_type":"localeString","en":"Add company","ru":"Добавить компанию"},"add-implementation":{"en":"Add deployment","ru":"Добавить внедрение","_type":"localeString"},"sort-title-asc":{"ru":"От А до Я","_type":"localeString","en":"From A to Z"},"sort-title-desc":{"_type":"localeString","en":"From Z to A","ru":"От Я до А"},"sellers-field":{"_type":"localeString","en":"Sellers","ru":"Поставщики, Производители"},"supply-types":{"_type":"localeString","en":"Supply type","ru":"Тип поставки"},"with-comments-checkbox":{"_type":"localeString","en":"With comments","ru":"С комментариями"},"supplier":{"en":"Supplier","ru":"Поставщик","_type":"localeString"},"vendor":{"ru":"Производитель","_type":"localeString","en":"Vendor"},"user":{"ru":"Пользователь","_type":"localeString","en":"User"},"company-type":{"ru":"Тип компании","_type":"localeString","en":"Company type"},"partners-field":{"en":"Partners","ru":" Партнеры","_type":"localeString"},"customers":{"ru":"Покупатели","_type":"localeString","en":"Customers"},"product-supplier":{"ru":"Поставщик продукта","_type":"localeString","en":"Product supplier"},"product-vendor":{"ru":"Производитель продукта","_type":"localeString","en":"Product vendor"},"implementation-date":{"_type":"localeString","en":"Deployment date","ru":"Дата внедрения"},"canceled":{"en":"Canceled","ru":"Отменено","_type":"localeString"},"deal-canceled":{"ru":"Сделка отменена","_type":"localeString","en":"Deal canceled"},"deal-closed":{"en":"Deal closed","ru":"Сделка закрыта","_type":"localeString"},"deal-in-progress":{"en":"Deal in progress","ru":"Сделка в процессе","_type":"localeString"},"deal-is-planned":{"ru":"Сделка планируется","_type":"localeString","en":"Deal is planned"},"finished":{"en":"Finished","ru":"Завершено","_type":"localeString"},"in-process":{"_type":"localeString","en":"In Process","ru":"Ведется"},"planned":{"ru":"Планируется","_type":"localeString","en":"Planned"},"proof-of-concept":{"en":"Proof of concept","ru":"Пилотный проект","_type":"localeString"},"stopped":{"ru":"Остановлено","_type":"localeString","en":"Stopped"},"competencies":{"ru":"Компетенции","_type":"localeString","en":"Competencies"}}},"translationsStatus":{"implementations":"success","filters":"success"},"sections":{"implementations-text-block":{"label":"catalog-implementations-text-block","body":{"_type":"localeBlock","en":[{"children":[{"marks":[],"text":"The ROI4CIO Deployment Catalog is a database of software, hardware, and IT service implementations. Find implementations by vendor, supplier, user, business tasks, problems, status, filter by the presence of ROI and reference.","_key":"0e40f9075bd00","_type":"span"}],"_type":"block","style":"normal","_key":"0e40f9075bd0","markDefs":[]}],"ru":[{"children":[{"marks":[],"text":"Каталог внедрений ROI4CIO - это база данных о внедрениях программного обеспечения, оборудования и ИТ-услуг. Находите внедрения по вендору, поставщику, пользователю, бизнес-задачам, проблемам, статусу, фильтруйте по наличию ROI и референса.","_key":"1435aa0421110","_type":"span"}],"_type":"block","style":"normal","_key":"1435aa042111","markDefs":[]}]}}},"sectionsStatus":{"implementations-text-block":"success"},"pageMetaData":{"implementations":{"title":{"ru":"ROI4CIO: Внедрения","_type":"localeString","en":"ROI4CIO: Implementations"},"meta":[{"name":"og:image","content":"https://roi4cio.com/fileadmin/templates/roi4cio/image/roi4cio-logobig.jpg"},{"content":"website","name":"og:type"}],"translatable_meta":[{"translations":{"ru":"Внедрения","_type":"localeString","en":"Deployments"},"name":"og:title"},{"name":"og:description","translations":{"ru":"Каталог внедрений различных видов программного обеспечения, ИТ проектов. Результаты внедрений ИТ, результаты, референсы, ROI","_type":"localeString","en":"Implementations"}},{"translations":{"en":"Implementations","ru":"Внедрения","_type":"localeString"},"name":"title"},{"name":"description","translations":{"_type":"localeString","en":"Implementations description","ru":"Описание внедрений"}},{"name":"keywords","translations":{"ru":"Внедрения ключевые слова","_type":"localeString","en":"Implementations keywords"}}]}},"pageMetaDataStatus":{"implementations":"success"},"subscribeInProgress":false,"subscribeError":false},"auth":{"inProgress":false,"error":false,"checked":true,"initialized":false,"user":{},"role":null,"expires":null},"products":{"productsByAlias":{},"aliases":{},"links":{},"meta":{},"loading":false,"error":null,"useProductLoading":false,"sellProductLoading":false,"templatesById":{},"comparisonByTemplateId":{}},"filters":{"filterCriterias":{"loading":false,"error":null,"data":{"price":{"min":0,"max":6000},"users":{"loading":false,"error":null,"ids":[],"values":{}},"suppliers":{"loading":false,"error":null,"ids":[],"values":{}},"vendors":{"loading":false,"error":null,"ids":[],"values":{}},"roles":{"id":200,"title":"Roles","values":{"1":{"id":1,"title":"User","translationKey":"user"},"2":{"id":2,"title":"Supplier","translationKey":"supplier"},"3":{"id":3,"title":"Vendor","translationKey":"vendor"}}},"categories":{"flat":[],"tree":[]},"countries":{"loading":false,"error":null,"ids":[],"values":{}}}},"showAIFilter":false},"companies":{"companiesByAlias":{},"aliases":{},"links":{},"meta":{},"loading":false,"error":null},"implementations":{"implementationsByAlias":{"hp-3par-storeserv-hp-bladesystem-hp-bl-servers-to-software-developer-in-the-field-of-public-health":{"id":951,"title":"HP 3PAR StoreServ, HP Bladesystem, HP BL servers to software developer in the field of public health","description":"Description is not ready yet","alias":"hp-3par-storeserv-hp-bladesystem-hp-bl-servers-to-software-developer-in-the-field-of-public-health","roi":0,"seo":{"title":"HP 3PAR StoreServ, HP Bladesystem, HP BL servers to software developer in the field of public health","keywords":"","description":"Description is not ready yet","og:title":"HP 3PAR StoreServ, HP Bladesystem, HP BL servers to software developer in the field of public health","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":7355,"title":"EngagePoint (User)","logoURL":"https://old.roi4cio.com/uploads/roi/company/EngagePoint_01.jpg","alias":"engagepoint-user","address":"Киевв, 01133, ул. Кутузова, 18/7","roles":[],"description":" EngagePoint – is an American healthcare software and IT Services company with the development centre in Kyiv. EngagePoint accelerates the government’s transition to a modern, integrated, sustainable enterprise by delivering software and services for program modernization, program administration and program integrity. EngagePoint was founded in 2007 and recognized as one of the fastest growing companies in North America on Deloitte’s 2013 Technology Fast 500. EngagePoint is a member of American Chamber of Commerce in Ukraine and Hi-Tech Initiative IT Association.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":1,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://www.engagepoint.com/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"EngagePoint (User)","keywords":"","description":" EngagePoint – is an American healthcare software and IT Services company with the development centre in Kyiv. EngagePoint accelerates the government’s transition to a modern, integrated, sustainable enterprise by delivering software and services for program m","og:title":"EngagePoint (User)","og:description":" EngagePoint – is an American healthcare software and IT Services company with the development centre in Kyiv. EngagePoint accelerates the government’s transition to a modern, integrated, sustainable enterprise by delivering software and services for program m","og:image":"https://old.roi4cio.com/uploads/roi/company/EngagePoint_01.jpg"},"eventUrl":""},"supplier":{"id":249,"title":"Integrity Systems","logoURL":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png","alias":"integrity-systems","address":"Київ 01032 вул. Саксаганського, 119, оф. 26","roles":[],"description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its activities on solutions using various technologies IT business objectives corporate customers in Ukraine. The main asset is our team of qualified consultants, project managers and engineers, allowing us to offer our clients services that cover the full life cycle of IT solutions - from analyzing business objectives, design, implementation and further maintenance and support.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":197,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":9,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://integritysys.com.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Integrity Systems","keywords":"Systems, solutions, Integrity, implementation, design, company, business, objectives","description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:title":"Integrity Systems","og:description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:image":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":48,"logo":false,"scheme":false,"title":"HPE 3PAR StoreServ","vendorVerified":0,"rating":"2.00","implementationsCount":3,"suppliersCount":0,"alias":"hpe-3par-storeserv","companyTypes":[],"description":"<span style=\"background-color: rgb(252, 252, 252); color: rgb(51, 51, 51); font-family: "Metric Light", Arial, sans-serif; font-size: 18px; \">HPE 3PAR StoreServ Storage is a new class of enterprise flash arrays with greater than 3M IOPS, sub-millisecond latencies, a 6x density advantage, and scalability of over 20 PiB of usable capacity for massive consolidation. </span>","shortDescription":"HPE 3PAR StoreServ Scalable to Meet Growing Enterprise Requirements.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":6,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE 3PAR StoreServ","keywords":"StoreServ, 3PAR, scalability, advantage, over, density, usable, massive","description":"<span style=\"background-color: rgb(252, 252, 252); color: rgb(51, 51, 51); font-family: "Metric Light", Arial, sans-serif; font-size: 18px; \">HPE 3PAR StoreServ Storage is a new class of enterprise flash arrays with greater than 3M IOPS, sub-millisec","og:title":"HPE 3PAR StoreServ","og:description":"<span style=\"background-color: rgb(252, 252, 252); color: rgb(51, 51, 51); font-family: "Metric Light", Arial, sans-serif; font-size: 18px; \">HPE 3PAR StoreServ Storage is a new class of enterprise flash arrays with greater than 3M IOPS, sub-millisec"},"eventUrl":"","translationId":103,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":501,"title":"All-flash and Hybrid Storage","alias":"all-flash-and-hybrid-storage","description":" Costs have come down making hybrid and all-flash enterprise storage solutions the preferred choice for storing, processing and moving the massive volumes of business data generated in today’s cloud, mobile and IoT environment.\r\nll-flash storage arrays utilize solid-state drives (SSDs) to deliver high-performance and low-latency workloads using data compression and deduplication technologies. Hybrid Storage combines those same solid-state drives (SSDs) with SAS or NL-SAS drives to offer a more cost-effective storage solution that balances cost with superior performance and high storage density.\r\nBoth options lower the complexity of providing scale-out performance at ultralow latency for data-intensive loads and big data analytics.\r\nWhether you are building a new storage array or refreshing your existing storage infrastructure we will work with you to plan, source, install and configure a storage solution to meet you budgetary and business requirements.","materialsDescription":" <span style=\"font-weight: bold;\">What is flash storage and what is it used for?</span>\r\nFlash storage is any storage repository that uses flash memory. Flash memory comes in many form factors, and you probably use flash storage every day. From a single Flash chip on a simple circuit board attached to your computing device via USB to circuit boards in your phone or MP3 player, to a fully integrated “Enterprise Flash Disk” where lots of chips are attached to a circuit board in a form factor that can be used in place of a spinning disk.\r\n<span style=\"font-weight: bold;\">What is flash storage SSD?</span>\r\nA “Solid State Disk” or EFD “Enterprise Flash Disk” is a fully integrated circuit board where many Flash chips are engineered to represent a single Flash disk. Primarily used to replace a traditional spinning disk, SSDs are used in MP3 players, laptops, servers and enterprise storage systems.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and SSD?</span>\r\nFlash storage is a reference to any device that can function as a storage repository. Flash storage can be a simple USB device or a fully integrated All-Flash Storage Array. SSD, “Solid State Disk” is an integrated device designed to replace spinning media, commonly used in enterprise storage arrays.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and traditional hard drives?</span>\r\nA traditional hard drive leveraged rotating platters and heads to read data from a magnetic device, comparable to a traditional record player; while flash storage leveraged electronic media or flash memory, to vastly improve performance. Flash eliminates rotational delay and seeks time, functions that add latency to traditional storage media.\r\n<span style=\"font-weight: bold;\">What is the difference between an all-flash array and a hybrid array?</span>\r\nA Hybrid Storage Array uses a combination of spinning disk drives and Flash SSD. Along with the right software, a Hybrid Array can be configured to improve overall performance while reducing cost. An All-Flash-Array is designed to support only SSD media.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Al_flash_and_Hybrid_Storage.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":417,"logo":false,"scheme":false,"title":"HPE BladeSystem c7000 Enclosures","vendorVerified":0,"rating":"2.40","implementationsCount":12,"suppliersCount":0,"alias":"hpe-bladesystem-c7000-enclosures","companyTypes":[],"description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.\r\n\r\nWhat's new\r\nUniversal high voltage power solution for reduced Datacenter CAPEX & OPEX - 2650W power supply with a wide ranging input supporting 277VAC & 380VDC - Power input module with APP Saf-D-Grid connectors\r\n<span style=\"font-weight: bold;\">Features</span>\r\nExtending the foundation for Converged Infrastructure\r\nThe HP BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.\r\nWith demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.\r\nHP OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.\r\nWith Onboard Administrator, iLO remote management, and HP OneView you can manage your servers and take complete control regardless of the state of the server operating system.","shortDescription":"The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years. The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":11,"sellingCount":9,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE BladeSystem c7000 Enclosures","keywords":"input, with, power, management, server, Power, storage, Infrastructure","description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i","og:title":"HPE BladeSystem c7000 Enclosures","og:description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i"},"eventUrl":"","translationId":418,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":4,"title":"Reduce Costs"},{"id":6,"title":"Ensure Security and Business Continuity"},{"id":8,"title":"Reduce Production Timelines"},{"id":254,"title":"Centralize management"},{"id":306,"title":"Manage Risks"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":175,"title":"Aging IT infrastructure"},{"id":177,"title":"Decentralized IT systems"},{"id":342,"title":"Total high cost of ownership of IT infrastructure (TCO)"},{"id":348,"title":"No centralized control over IT systems"},{"id":373,"title":"IT infrastructure does not meet business tasks"},{"id":392,"title":"Lengthy production timelines"},{"id":397,"title":"Insufficient risk management"}]}},"categories":[{"id":501,"title":"All-flash and Hybrid Storage","alias":"all-flash-and-hybrid-storage","description":" Costs have come down making hybrid and all-flash enterprise storage solutions the preferred choice for storing, processing and moving the massive volumes of business data generated in today’s cloud, mobile and IoT environment.\r\nll-flash storage arrays utilize solid-state drives (SSDs) to deliver high-performance and low-latency workloads using data compression and deduplication technologies. Hybrid Storage combines those same solid-state drives (SSDs) with SAS or NL-SAS drives to offer a more cost-effective storage solution that balances cost with superior performance and high storage density.\r\nBoth options lower the complexity of providing scale-out performance at ultralow latency for data-intensive loads and big data analytics.\r\nWhether you are building a new storage array or refreshing your existing storage infrastructure we will work with you to plan, source, install and configure a storage solution to meet you budgetary and business requirements.","materialsDescription":" <span style=\"font-weight: bold;\">What is flash storage and what is it used for?</span>\r\nFlash storage is any storage repository that uses flash memory. Flash memory comes in many form factors, and you probably use flash storage every day. From a single Flash chip on a simple circuit board attached to your computing device via USB to circuit boards in your phone or MP3 player, to a fully integrated “Enterprise Flash Disk” where lots of chips are attached to a circuit board in a form factor that can be used in place of a spinning disk.\r\n<span style=\"font-weight: bold;\">What is flash storage SSD?</span>\r\nA “Solid State Disk” or EFD “Enterprise Flash Disk” is a fully integrated circuit board where many Flash chips are engineered to represent a single Flash disk. Primarily used to replace a traditional spinning disk, SSDs are used in MP3 players, laptops, servers and enterprise storage systems.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and SSD?</span>\r\nFlash storage is a reference to any device that can function as a storage repository. Flash storage can be a simple USB device or a fully integrated All-Flash Storage Array. SSD, “Solid State Disk” is an integrated device designed to replace spinning media, commonly used in enterprise storage arrays.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and traditional hard drives?</span>\r\nA traditional hard drive leveraged rotating platters and heads to read data from a magnetic device, comparable to a traditional record player; while flash storage leveraged electronic media or flash memory, to vastly improve performance. Flash eliminates rotational delay and seeks time, functions that add latency to traditional storage media.\r\n<span style=\"font-weight: bold;\">What is the difference between an all-flash array and a hybrid array?</span>\r\nA Hybrid Storage Array uses a combination of spinning disk drives and Flash SSD. Along with the right software, a Hybrid Array can be configured to improve overall performance while reducing cost. An All-Flash-Array is designed to support only SSD media.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Al_flash_and_Hybrid_Storage.png"},{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"-1","functionallyTaskAssignment":"-1","projectWasPut":"-1","price":0,"source":{"url":"https://ko.com.ua//ne_roskosh_a_neobhodimost_107815","title":"Media"}},"comments":[],"referencesCount":0},"hp-bl-servers-and-hp-eva-storage-for-ibox":{"id":945,"title":"HP BL Servers and HP EVA Storage for iBox","description":"Description is not ready yet","alias":"hp-bl-servers-and-hp-eva-storage-for-ibox","roi":0,"seo":{"title":"HP BL Servers and HP EVA Storage for iBox","keywords":"","description":"Description is not ready yet","og:title":"HP BL Servers and HP EVA Storage for iBox","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":7351,"title":"IBox","logoURL":"https://old.roi4cio.com/uploads/roi/company/ibox.jpg","alias":"ibox","address":"","roles":[],"description":"The “Ibox” company has been working on payment acceptance market since 1991. The business in Ukraine started in 2006.<br />Our company is an absolute leader according to the main efficiency indicators. The network consists of more than 5800 payment terminals all over Ukraine, installed within the sales areas, in the largest retail and gas networks as well as in various stores in 200 cities around Ukraine. IBox terminals allow to do quick and easy financial transactions at a time when necessary in comfortable places. The company has about 450 services from different operators that accept payments from private clients. <br />More than a million customers prefer to make payments every day using Ibox terminals. Creating and developing the payment service “Pay Instantly. IBox Payments”, the company brings to the relationship with clients and partners the idea of natural simplicity and transparency, credibility and confidence.<br />The company is constantly expanding its range services and actively looks into the future.<br />Source: https://www.linkedin.com/company/ibox_3/about/","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":1,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"https://ibox.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"IBox","keywords":"","description":"The “Ibox” company has been working on payment acceptance market since 1991. The business in Ukraine started in 2006.<br />Our company is an absolute leader according to the main efficiency indicators. The network consists of more than 5800 payment termi","og:title":"IBox","og:description":"The “Ibox” company has been working on payment acceptance market since 1991. The business in Ukraine started in 2006.<br />Our company is an absolute leader according to the main efficiency indicators. The network consists of more than 5800 payment termi","og:image":"https://old.roi4cio.com/uploads/roi/company/ibox.jpg"},"eventUrl":""},"supplier":{"id":249,"title":"Integrity Systems","logoURL":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png","alias":"integrity-systems","address":"Київ 01032 вул. Саксаганського, 119, оф. 26","roles":[],"description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its activities on solutions using various technologies IT business objectives corporate customers in Ukraine. The main asset is our team of qualified consultants, project managers and engineers, allowing us to offer our clients services that cover the full life cycle of IT solutions - from analyzing business objectives, design, implementation and further maintenance and support.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":197,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":9,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://integritysys.com.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Integrity Systems","keywords":"Systems, solutions, Integrity, implementation, design, company, business, objectives","description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:title":"Integrity Systems","og:description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:image":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":419,"logo":false,"scheme":false,"title":"HP EVA Storage","vendorVerified":0,"rating":"2.00","implementationsCount":9,"suppliersCount":0,"alias":"hp-eva-storage","companyTypes":[],"description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, mid-sized organizations count on HP EVA Storage. This fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.\r\n\r\nFor medium-sized companies:\r\nDecrease storage management cost by 20-30%.1\r\nBalance price and performance with dynamic storage tiering and non-disruptive data migration.","shortDescription":"HP EVA Storage - fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":18,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP EVA Storage","keywords":"storage, data, while, availability, Storage, increasing, organizations, productivity","description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m","og:title":"HP EVA Storage","og:description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m"},"eventUrl":"","translationId":420,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":6,"title":"Ensure Security and Business Continuity"},{"id":7,"title":"Improve Customer Service"},{"id":10,"title":"Ensure Compliance"},{"id":254,"title":"Centralize management"},{"id":306,"title":"Manage Risks"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":177,"title":"Decentralized IT systems"},{"id":340,"title":"Low quality of customer service"},{"id":350,"title":"No monitoring of corporate IT processes"},{"id":370,"title":"No automated business processes"},{"id":394,"title":"Shortage of information for decision making"},{"id":397,"title":"Insufficient risk management"}]}},"categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"-1","functionallyTaskAssignment":"-1","projectWasPut":"-1","price":0,"source":{"url":"https://ko.com.ua/vremya_dengi_68929","title":"Media"}},"comments":[],"referencesCount":0},"hp-bladesystem-and-hp-3par-for-the-operator-of-the-system-of-main-oil-pipelines-of-ukraine":{"id":961,"title":"HP BladeSystem and HP 3PAR for the operator of the system of main oil pipelines of Ukraine","description":"Description is not ready yet","alias":"hp-bladesystem-and-hp-3par-for-the-operator-of-the-system-of-main-oil-pipelines-of-ukraine","roi":0,"seo":{"title":"HP BladeSystem and HP 3PAR for the operator of the system of main oil pipelines of Ukraine","keywords":"","description":"Description is not ready yet","og:title":"HP BladeSystem and HP 3PAR for the operator of the system of main oil pipelines of Ukraine","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":7233,"title":"Ukrtransneft (Ukrtransnafta)","logoURL":"https://old.roi4cio.com/uploads/roi/company/ukrtransneft.png","alias":"ukrtransneft-ukrtransnafta","address":"","roles":[],"description":"Public Joint Stock Company <b>“Ukrtransnafta”</b> was created in 2001 on the basis of State-Owned Joint Stock Company «Main Pipelines «Druzhba» and State-Owned Joint Stock Company «Prydniprovski Main Pipelines” (which are the Company’s branches at present) for the purpose of optimizing the operation of Ukraine’s oil transportation system and implementing a uniform policy in this field. In 2007, a branch styled “Pivdenni Main Pipelines” were created within the Company by a resolution of the Shareholders of Open Joint Stock Company “Ukrtransnafta” dated August 10, 2007.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":1,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"https://www.ukrtransnafta.com/ru/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Ukrtransneft (Ukrtransnafta)","keywords":"","description":"Public Joint Stock Company <b>“Ukrtransnafta”</b> was created in 2001 on the basis of State-Owned Joint Stock Company «Main Pipelines «Druzhba» and State-Owned Joint Stock Company «Prydniprovski Main Pipelines” (which are the Company’s branches at present) for","og:title":"Ukrtransneft (Ukrtransnafta)","og:description":"Public Joint Stock Company <b>“Ukrtransnafta”</b> was created in 2001 on the basis of State-Owned Joint Stock Company «Main Pipelines «Druzhba» and State-Owned Joint Stock Company «Prydniprovski Main Pipelines” (which are the Company’s branches at present) for","og:image":"https://old.roi4cio.com/uploads/roi/company/ukrtransneft.png"},"eventUrl":""},"supplier":{"id":201,"title":"IT Solutions Ukraine","logoURL":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg","alias":"it-solutions-ukraine","address":"04050, г. Киев , ул. Студенческая, 3","roles":[],"description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field of IT consulting and information security. Fulfills orders for large commercial and state organizations in all regions of Ukraine.<br />When developing possible solutions for the project, the requirements of the customer and the particular infrastructure of the enterprise are taken into account. After that, solutions are offered based on the hardware and software of the world's leading partner manufacturers: HPE, HP inc., Cisco, Lenovo, NetApp, VMware, Oracle, Huawei, Microsoft, TrueConf, APC, MobileIron, ESET, IBM, Fortinet, Veritas, Dell-emc\r\n<span style=\"font-weight: bold;\">IT-Solutions Services</span><br />IT Infrastructure Solutions:\r\n<ul><li>physical (data storage systems, servers, data transmission and cybersecurity devices, construction of server and data processing centers, SCS, VKS, uninterruptible power supply, personal equipment, peripherals, software)</li></ul>\r\n<ul><li>virtualized (servers, storage, network, desktops)</li></ul>\r\n<ul><li>on information security (network, users, email, information security and security events management)</li></ul>\r\nDesign and implementation of infrastructure services:\r\n<ul><li>backup systems</li></ul>\r\n<ul><li>virtualization</li></ul>\r\n<ul><li>cloud services</li></ul>\r\n<ul><li>IT Service Management (ITSM)</li></ul>\r\n<ul><li>information security</li></ul>\r\n<ul><li>monitoring and control systems</li></ul>\r\nConsulting:\r\n<ul><li>data management (storage, backup, recovery)</li></ul>\r\n<ul><li>IT service continuity</li></ul>\r\n<ul><li>analytics (IT audit, business analytics, vScore - preliminary performance assessment for the implementation of virtualization, dScore - data management performance assessment)</li></ul>\r\n<ul><li>Information Security</li></ul>","companyTypes":[],"products":{},"vendoredProductsCount":2,"suppliedProductsCount":228,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":14,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://it-solutions.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"IT Solutions Ukraine","keywords":"Partner, Solutions, projects, Gold, Silver, Business, Enterprise, VMware","description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:title":"IT Solutions Ukraine","og:description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:image":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":48,"logo":false,"scheme":false,"title":"HPE 3PAR StoreServ","vendorVerified":0,"rating":"2.00","implementationsCount":3,"suppliersCount":0,"alias":"hpe-3par-storeserv","companyTypes":[],"description":"<span style=\"background-color: rgb(252, 252, 252); color: rgb(51, 51, 51); font-family: "Metric Light", Arial, sans-serif; font-size: 18px; \">HPE 3PAR StoreServ Storage is a new class of enterprise flash arrays with greater than 3M IOPS, sub-millisecond latencies, a 6x density advantage, and scalability of over 20 PiB of usable capacity for massive consolidation. </span>","shortDescription":"HPE 3PAR StoreServ Scalable to Meet Growing Enterprise Requirements.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":6,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE 3PAR StoreServ","keywords":"StoreServ, 3PAR, scalability, advantage, over, density, usable, massive","description":"<span style=\"background-color: rgb(252, 252, 252); color: rgb(51, 51, 51); font-family: "Metric Light", Arial, sans-serif; font-size: 18px; \">HPE 3PAR StoreServ Storage is a new class of enterprise flash arrays with greater than 3M IOPS, sub-millisec","og:title":"HPE 3PAR StoreServ","og:description":"<span style=\"background-color: rgb(252, 252, 252); color: rgb(51, 51, 51); font-family: "Metric Light", Arial, sans-serif; font-size: 18px; \">HPE 3PAR StoreServ Storage is a new class of enterprise flash arrays with greater than 3M IOPS, sub-millisec"},"eventUrl":"","translationId":103,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":501,"title":"All-flash and Hybrid Storage","alias":"all-flash-and-hybrid-storage","description":" Costs have come down making hybrid and all-flash enterprise storage solutions the preferred choice for storing, processing and moving the massive volumes of business data generated in today’s cloud, mobile and IoT environment.\r\nll-flash storage arrays utilize solid-state drives (SSDs) to deliver high-performance and low-latency workloads using data compression and deduplication technologies. Hybrid Storage combines those same solid-state drives (SSDs) with SAS or NL-SAS drives to offer a more cost-effective storage solution that balances cost with superior performance and high storage density.\r\nBoth options lower the complexity of providing scale-out performance at ultralow latency for data-intensive loads and big data analytics.\r\nWhether you are building a new storage array or refreshing your existing storage infrastructure we will work with you to plan, source, install and configure a storage solution to meet you budgetary and business requirements.","materialsDescription":" <span style=\"font-weight: bold;\">What is flash storage and what is it used for?</span>\r\nFlash storage is any storage repository that uses flash memory. Flash memory comes in many form factors, and you probably use flash storage every day. From a single Flash chip on a simple circuit board attached to your computing device via USB to circuit boards in your phone or MP3 player, to a fully integrated “Enterprise Flash Disk” where lots of chips are attached to a circuit board in a form factor that can be used in place of a spinning disk.\r\n<span style=\"font-weight: bold;\">What is flash storage SSD?</span>\r\nA “Solid State Disk” or EFD “Enterprise Flash Disk” is a fully integrated circuit board where many Flash chips are engineered to represent a single Flash disk. Primarily used to replace a traditional spinning disk, SSDs are used in MP3 players, laptops, servers and enterprise storage systems.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and SSD?</span>\r\nFlash storage is a reference to any device that can function as a storage repository. Flash storage can be a simple USB device or a fully integrated All-Flash Storage Array. SSD, “Solid State Disk” is an integrated device designed to replace spinning media, commonly used in enterprise storage arrays.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and traditional hard drives?</span>\r\nA traditional hard drive leveraged rotating platters and heads to read data from a magnetic device, comparable to a traditional record player; while flash storage leveraged electronic media or flash memory, to vastly improve performance. Flash eliminates rotational delay and seeks time, functions that add latency to traditional storage media.\r\n<span style=\"font-weight: bold;\">What is the difference between an all-flash array and a hybrid array?</span>\r\nA Hybrid Storage Array uses a combination of spinning disk drives and Flash SSD. Along with the right software, a Hybrid Array can be configured to improve overall performance while reducing cost. An All-Flash-Array is designed to support only SSD media.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Al_flash_and_Hybrid_Storage.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":4,"title":"Reduce Costs"},{"id":6,"title":"Ensure Security and Business Continuity"},{"id":254,"title":"Centralize management"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":395,"title":"Decentralization of management"},{"id":400,"title":"High costs"}]}},"categories":[{"id":501,"title":"All-flash and Hybrid Storage","alias":"all-flash-and-hybrid-storage","description":" Costs have come down making hybrid and all-flash enterprise storage solutions the preferred choice for storing, processing and moving the massive volumes of business data generated in today’s cloud, mobile and IoT environment.\r\nll-flash storage arrays utilize solid-state drives (SSDs) to deliver high-performance and low-latency workloads using data compression and deduplication technologies. Hybrid Storage combines those same solid-state drives (SSDs) with SAS or NL-SAS drives to offer a more cost-effective storage solution that balances cost with superior performance and high storage density.\r\nBoth options lower the complexity of providing scale-out performance at ultralow latency for data-intensive loads and big data analytics.\r\nWhether you are building a new storage array or refreshing your existing storage infrastructure we will work with you to plan, source, install and configure a storage solution to meet you budgetary and business requirements.","materialsDescription":" <span style=\"font-weight: bold;\">What is flash storage and what is it used for?</span>\r\nFlash storage is any storage repository that uses flash memory. Flash memory comes in many form factors, and you probably use flash storage every day. From a single Flash chip on a simple circuit board attached to your computing device via USB to circuit boards in your phone or MP3 player, to a fully integrated “Enterprise Flash Disk” where lots of chips are attached to a circuit board in a form factor that can be used in place of a spinning disk.\r\n<span style=\"font-weight: bold;\">What is flash storage SSD?</span>\r\nA “Solid State Disk” or EFD “Enterprise Flash Disk” is a fully integrated circuit board where many Flash chips are engineered to represent a single Flash disk. Primarily used to replace a traditional spinning disk, SSDs are used in MP3 players, laptops, servers and enterprise storage systems.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and SSD?</span>\r\nFlash storage is a reference to any device that can function as a storage repository. Flash storage can be a simple USB device or a fully integrated All-Flash Storage Array. SSD, “Solid State Disk” is an integrated device designed to replace spinning media, commonly used in enterprise storage arrays.\r\n<span style=\"font-weight: bold;\">What is the difference between flash storage and traditional hard drives?</span>\r\nA traditional hard drive leveraged rotating platters and heads to read data from a magnetic device, comparable to a traditional record player; while flash storage leveraged electronic media or flash memory, to vastly improve performance. Flash eliminates rotational delay and seeks time, functions that add latency to traditional storage media.\r\n<span style=\"font-weight: bold;\">What is the difference between an all-flash array and a hybrid array?</span>\r\nA Hybrid Storage Array uses a combination of spinning disk drives and Flash SSD. Along with the right software, a Hybrid Array can be configured to improve overall performance while reducing cost. An All-Flash-Array is designed to support only SSD media.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Al_flash_and_Hybrid_Storage.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"","functionallyTaskAssignment":"","projectWasPut":"","price":0,"source":{"url":"https://it-solutions.ua/portfolio/ukrtransnafta/","title":"Supplier's web site"}},"comments":[],"referencesCount":0},"bladesystem-c7000-hp-eva-hp-bl-servers-for-retail-allo-network":{"id":946,"title":"HP BladeSystem c7000, HP EVA, HP BL servers for retail Allo network","description":"Description is not ready yet","alias":"bladesystem-c7000-hp-eva-hp-bl-servers-for-retail-allo-network","roi":0,"seo":{"title":"HP BladeSystem c7000, HP EVA, HP BL servers for retail Allo network","keywords":"","description":"Description is not ready yet","og:title":"HP BladeSystem c7000, HP EVA, HP BL servers for retail Allo network","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":7352,"title":"Allo (User)","logoURL":"https://old.roi4cio.com/uploads/roi/company/allo_01.png","alias":"allo","address":"Киев, пр. Московский, 8","roles":[],"description":"<span style=\"font-weight: bold;\">Group of Companies "ALLO"</span>\r\n\r\n<ul><li>Retail network "Allo Telecom"</li> </ul>","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":4,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":1,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":1,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://allo.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Allo (User)","keywords":"Allo, TelecomWholesale, division, Tsifroteh, network, Retail, Companies, ALLO","description":"<div><span style=\"font-weight: bold;\">Group of Companies "ALLO"</span></div>\r\n<div></div>\r\n<div><ul><li>Retail network "Allo Telecom"</li> </ul></div>","og:title":"Allo (User)","og:description":"<div><span style=\"font-weight: bold;\">Group of Companies "ALLO"</span></div>\r\n<div></div>\r\n<div><ul><li>Retail network "Allo Telecom"</li> </ul></div>","og:image":"https://old.roi4cio.com/uploads/roi/company/allo_01.png"},"eventUrl":""},"supplier":{"id":249,"title":"Integrity Systems","logoURL":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png","alias":"integrity-systems","address":"Київ 01032 вул. Саксаганського, 119, оф. 26","roles":[],"description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its activities on solutions using various technologies IT business objectives corporate customers in Ukraine. The main asset is our team of qualified consultants, project managers and engineers, allowing us to offer our clients services that cover the full life cycle of IT solutions - from analyzing business objectives, design, implementation and further maintenance and support.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":197,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":9,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://integritysys.com.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Integrity Systems","keywords":"Systems, solutions, Integrity, implementation, design, company, business, objectives","description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:title":"Integrity Systems","og:description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:image":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":417,"logo":false,"scheme":false,"title":"HPE BladeSystem c7000 Enclosures","vendorVerified":0,"rating":"2.40","implementationsCount":12,"suppliersCount":0,"alias":"hpe-bladesystem-c7000-enclosures","companyTypes":[],"description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.\r\n\r\nWhat's new\r\nUniversal high voltage power solution for reduced Datacenter CAPEX & OPEX - 2650W power supply with a wide ranging input supporting 277VAC & 380VDC - Power input module with APP Saf-D-Grid connectors\r\n<span style=\"font-weight: bold;\">Features</span>\r\nExtending the foundation for Converged Infrastructure\r\nThe HP BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.\r\nWith demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.\r\nHP OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.\r\nWith Onboard Administrator, iLO remote management, and HP OneView you can manage your servers and take complete control regardless of the state of the server operating system.","shortDescription":"The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years. The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":11,"sellingCount":9,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE BladeSystem c7000 Enclosures","keywords":"input, with, power, management, server, Power, storage, Infrastructure","description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i","og:title":"HPE BladeSystem c7000 Enclosures","og:description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i"},"eventUrl":"","translationId":418,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":419,"logo":false,"scheme":false,"title":"HP EVA Storage","vendorVerified":0,"rating":"2.00","implementationsCount":9,"suppliersCount":0,"alias":"hp-eva-storage","companyTypes":[],"description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, mid-sized organizations count on HP EVA Storage. This fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.\r\n\r\nFor medium-sized companies:\r\nDecrease storage management cost by 20-30%.1\r\nBalance price and performance with dynamic storage tiering and non-disruptive data migration.","shortDescription":"HP EVA Storage - fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":18,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP EVA Storage","keywords":"storage, data, while, availability, Storage, increasing, organizations, productivity","description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m","og:title":"HP EVA Storage","og:description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m"},"eventUrl":"","translationId":420,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":6,"title":"Ensure Security and Business Continuity"},{"id":7,"title":"Improve Customer Service"},{"id":254,"title":"Centralize management"},{"id":306,"title":"Manage Risks"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":175,"title":"Aging IT infrastructure"},{"id":340,"title":"Low quality of customer service"},{"id":370,"title":"No automated business processes"},{"id":373,"title":"IT infrastructure does not meet business tasks"},{"id":397,"title":"Insufficient risk management"}]}},"categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"},{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"-1","functionallyTaskAssignment":"-1","projectWasPut":"-1","price":0,"source":{"url":"https://ko.com.ua/biznes_so_skorostyu_interneta_63934","title":"Media"}},"comments":[],"referencesCount":0},"hp-bladesystem-for-steel-plant":{"id":1063,"title":"HP BladeSystem for Steel Plant","description":"<span style=\"font-style: italic;\">Description is not ready yet</span>","alias":"hp-bladesystem-for-steel-plant","roi":0,"seo":{"title":"HP BladeSystem for Steel Plant","keywords":"","description":"<span style=\"font-style: italic;\">Description is not ready yet</span>","og:title":"HP BladeSystem for Steel Plant","og:description":"<span style=\"font-style: italic;\">Description is not ready yet</span>"},"deal_info":"","user":{"id":7349,"title":"Non-Ferrous Metals Plant","logoURL":"https://old.roi4cio.com/uploads/roi/company/zavod_cvetnykh_metallov.png","alias":"zavod-cvetnykh-metallov","address":"","roles":[],"description":"LIMITED LIABILITY COMPANY <b>\"NON-FERROUS METALS PLANT\"</b> is a leading metallurgical company in Ukraine and one of the largest producers of non-ferrous metal products in the CIS and abroad. Currently, the plant produces more than 1000 products from 100 metal grades from copper, nickel, and zinc . ZCM non-ferrous metal products have high reputation and recognition from our partners. ZCM today - it's powerful production and technical complex with a unique modern equipment, the latest advanced technology and highly qualified personnel. We were the first to obtain Quality System Management Certificate and since 1994 is a part of The International List of Non-ferrous Products Manufactures.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":1,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://www.azocm.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Non-Ferrous Metals Plant","keywords":"","description":"LIMITED LIABILITY COMPANY <b>\"NON-FERROUS METALS PLANT\"</b> is a leading metallurgical company in Ukraine and one of the largest producers of non-ferrous metal products in the CIS and abroad. Currently, the plant produces more than 1000 products from 100 metal","og:title":"Non-Ferrous Metals Plant","og:description":"LIMITED LIABILITY COMPANY <b>\"NON-FERROUS METALS PLANT\"</b> is a leading metallurgical company in Ukraine and one of the largest producers of non-ferrous metal products in the CIS and abroad. Currently, the plant produces more than 1000 products from 100 metal","og:image":"https://old.roi4cio.com/uploads/roi/company/zavod_cvetnykh_metallov.png"},"eventUrl":""},"supplier":{"id":6447,"title":"AM Integrator (AMI)","logoURL":"https://old.roi4cio.com/uploads/roi/company/am_integrator.png","alias":"am-integrator","address":"Illinska St., 14/6 Kiev, 04070 Ukraine","roles":[],"description":"AM INTEGRATOR Group of Companies is one of the leading IT operators in Ukraine, being a supplier and integrator of a wide range of solutions in the field of modern IT infrastructure, multimedia solutions, engineering infrastructure, business applications and integrated business security systems for medium and large enterprises, as well as the public sector. AM Integrator helps companies:\r\n<ul><li>increase risk manageability and business productivity;</li></ul>\r\n<ul><li>reduce costs;</li></ul>\r\n<ul><li>protect data.</li></ul>\r\nAM Integrator offers intelligent and flexible solutions, including cloud services, that will help you strategically transform your business using technologies and platforms of industry leaders.<br />The company offers solutions for increasing productivity, effective collaboration, mobility and relationship management, identity-driven, advanced analytics, or the Internet of things. AM Integrator also helps with core infrastructure, from support to creating disaster recovery solutions. The team of company experts has been working with cloud technologies for more than 5 years, with virtual environments - more than 10 years.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":116,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":21,"vendorImplementationsCount":0,"vendorPartnersCount":8,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://www.amintegrator.com/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"AM Integrator (AMI)","keywords":"","description":"AM INTEGRATOR Group of Companies is one of the leading IT operators in Ukraine, being a supplier and integrator of a wide range of solutions in the field of modern IT infrastructure, multimedia solutions, engineering infrastructure, business applications and i","og:title":"AM Integrator (AMI)","og:description":"AM INTEGRATOR Group of Companies is one of the leading IT operators in Ukraine, being a supplier and integrator of a wide range of solutions in the field of modern IT infrastructure, multimedia solutions, engineering infrastructure, business applications and i","og:image":"https://old.roi4cio.com/uploads/roi/company/am_integrator.png"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":6,"title":"Ensure Security and Business Continuity"},{"id":8,"title":"Reduce Production Timelines"},{"id":10,"title":"Ensure Compliance"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":175,"title":"Aging IT infrastructure"},{"id":342,"title":"Total high cost of ownership of IT infrastructure (TCO)"},{"id":373,"title":"IT infrastructure does not meet business tasks"},{"id":383,"title":"Shortage of inhouse IT engineers"},{"id":386,"title":"Risk of lost access to data and IT systems"}]}},"categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"-1","functionallyTaskAssignment":"-1","projectWasPut":"-1","price":0,"source":{"url":"https://b2blogger.com/pressroom/145602.html","title":"Media"}},"comments":[],"referencesCount":0},"hp-bladesystem-hp-eva-for-ukrainian-energy-company":{"id":963,"title":"HP BladeSystem, HP EVA for Ukrainian energy company","description":"Description is not ready yet","alias":"hp-bladesystem-hp-eva-for-ukrainian-energy-company","roi":0,"seo":{"title":"HP BladeSystem, HP EVA for Ukrainian energy company","keywords":"","description":"Description is not ready yet","og:title":"HP BladeSystem, HP EVA for Ukrainian energy company","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":465,"title":"Kyivoblenergo","logoURL":"https://old.roi4cio.com/uploads/roi/company/Kyivoblenergo.jpg","alias":"kyivoblenergo","address":"г.Киев, 04136, ул.Стеценко, 1а","roles":[],"description":"PJSC “Kyivoblenergo” (KOE) is the Ukrainian electricity distribution company specializes in electricity transmission and supplying to the consumers in the Kyiv region.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":2,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://www.koe.vsei.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Kyivoblenergo","keywords":"electricity, company, region, Kyiv, consumers, owned, leadi, supplying","description":"PJSC “Kyivoblenergo” (KOE) is the Ukrainian electricity distribution company specializes in electricity transmission and supplying to the consumers in the Kyiv region.","og:title":"Kyivoblenergo","og:description":"PJSC “Kyivoblenergo” (KOE) is the Ukrainian electricity distribution company specializes in electricity transmission and supplying to the consumers in the Kyiv region.","og:image":"https://old.roi4cio.com/uploads/roi/company/Kyivoblenergo.jpg"},"eventUrl":""},"supplier":{"id":201,"title":"IT Solutions Ukraine","logoURL":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg","alias":"it-solutions-ukraine","address":"04050, г. Киев , ул. Студенческая, 3","roles":[],"description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field of IT consulting and information security. Fulfills orders for large commercial and state organizations in all regions of Ukraine.<br />When developing possible solutions for the project, the requirements of the customer and the particular infrastructure of the enterprise are taken into account. After that, solutions are offered based on the hardware and software of the world's leading partner manufacturers: HPE, HP inc., Cisco, Lenovo, NetApp, VMware, Oracle, Huawei, Microsoft, TrueConf, APC, MobileIron, ESET, IBM, Fortinet, Veritas, Dell-emc\r\n<span style=\"font-weight: bold;\">IT-Solutions Services</span><br />IT Infrastructure Solutions:\r\n<ul><li>physical (data storage systems, servers, data transmission and cybersecurity devices, construction of server and data processing centers, SCS, VKS, uninterruptible power supply, personal equipment, peripherals, software)</li></ul>\r\n<ul><li>virtualized (servers, storage, network, desktops)</li></ul>\r\n<ul><li>on information security (network, users, email, information security and security events management)</li></ul>\r\nDesign and implementation of infrastructure services:\r\n<ul><li>backup systems</li></ul>\r\n<ul><li>virtualization</li></ul>\r\n<ul><li>cloud services</li></ul>\r\n<ul><li>IT Service Management (ITSM)</li></ul>\r\n<ul><li>information security</li></ul>\r\n<ul><li>monitoring and control systems</li></ul>\r\nConsulting:\r\n<ul><li>data management (storage, backup, recovery)</li></ul>\r\n<ul><li>IT service continuity</li></ul>\r\n<ul><li>analytics (IT audit, business analytics, vScore - preliminary performance assessment for the implementation of virtualization, dScore - data management performance assessment)</li></ul>\r\n<ul><li>Information Security</li></ul>","companyTypes":[],"products":{},"vendoredProductsCount":2,"suppliedProductsCount":228,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":14,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://it-solutions.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"IT Solutions Ukraine","keywords":"Partner, Solutions, projects, Gold, Silver, Business, Enterprise, VMware","description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:title":"IT Solutions Ukraine","og:description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:image":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":417,"logo":false,"scheme":false,"title":"HPE BladeSystem c7000 Enclosures","vendorVerified":0,"rating":"2.40","implementationsCount":12,"suppliersCount":0,"alias":"hpe-bladesystem-c7000-enclosures","companyTypes":[],"description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.\r\n\r\nWhat's new\r\nUniversal high voltage power solution for reduced Datacenter CAPEX & OPEX - 2650W power supply with a wide ranging input supporting 277VAC & 380VDC - Power input module with APP Saf-D-Grid connectors\r\n<span style=\"font-weight: bold;\">Features</span>\r\nExtending the foundation for Converged Infrastructure\r\nThe HP BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.\r\nWith demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.\r\nHP OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.\r\nWith Onboard Administrator, iLO remote management, and HP OneView you can manage your servers and take complete control regardless of the state of the server operating system.","shortDescription":"The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years. The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":11,"sellingCount":9,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE BladeSystem c7000 Enclosures","keywords":"input, with, power, management, server, Power, storage, Infrastructure","description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i","og:title":"HPE BladeSystem c7000 Enclosures","og:description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i"},"eventUrl":"","translationId":418,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":419,"logo":false,"scheme":false,"title":"HP EVA Storage","vendorVerified":0,"rating":"2.00","implementationsCount":9,"suppliersCount":0,"alias":"hp-eva-storage","companyTypes":[],"description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, mid-sized organizations count on HP EVA Storage. This fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.\r\n\r\nFor medium-sized companies:\r\nDecrease storage management cost by 20-30%.1\r\nBalance price and performance with dynamic storage tiering and non-disruptive data migration.","shortDescription":"HP EVA Storage - fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":18,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP EVA Storage","keywords":"storage, data, while, availability, Storage, increasing, organizations, productivity","description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m","og:title":"HP EVA Storage","og:description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m"},"eventUrl":"","translationId":420,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":6,"title":"Ensure Security and Business Continuity"},{"id":254,"title":"Centralize management"},{"id":306,"title":"Manage Risks"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":373,"title":"IT infrastructure does not meet business tasks"},{"id":374,"title":"IT infrastructure downtimes"},{"id":386,"title":"Risk of lost access to data and IT systems"},{"id":395,"title":"Decentralization of management"}]}},"categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"},{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"","functionallyTaskAssignment":"","projectWasPut":"","price":0,"source":{"url":"https://it-solutions.ua/portfolio/kievoblenergo/","title":"Supplier's web site"}},"comments":[],"referencesCount":0},"hp-bladesystem-hp-procurve-hp-bl-servers-for-kovalskaya-plant":{"id":964,"title":"HP BladeSystem, HP ProCurve, HP BL-servers for Kovalskaya plant","description":"Description is not ready yet","alias":"hp-bladesystem-hp-procurve-hp-bl-servers-for-kovalskaya-plant","roi":0,"seo":{"title":"HP BladeSystem, HP ProCurve, HP BL-servers for Kovalskaya plant","keywords":"","description":"Description is not ready yet","og:title":"HP BladeSystem, HP ProCurve, HP BL-servers for Kovalskaya plant","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":7491,"title":"KOVALSKA Industrial-Construction Group","logoURL":"https://old.roi4cio.com/uploads/roi/company/Kovalska.jpg","alias":"kovalskaja-promyshlenno-stroitelnaja-gruppa","address":"","roles":[],"description":" ICG Kovalska - (full name: Association "Industrial and Construction Group" Kovalska ") - Ukrainian manufacturer of building materials and builder. It is a part of Joint Stock Company «Reinforced Concrete Structures Plant. Svetlana Kowalska ”, and at that time the Reinforced Concrete Products Factory No. 3 was founded in 1956.\r\nToday, Kovalska PBG brings together 11 enterprises, 28 concrete mixing units. The Group's activities are based on the production of granite raw materials, manufactured building materials (concrete mixes, reinforced concrete products, concrete elements of landscape design, dry mixes, paints and decorative plaster), providing transportation for its customers, designing, erecting and operating facilities commercial and social purpose.<br />\r\nPlant of Reinforced Concrete Structures. Svetlana Kowalska<br />\r\nThe Group's companies have 3,500 employees\r\nSource: https://uk.wikipedia.org/wiki/%D0%9F%D0%91%D0%93_%C2%AB%D0%9A%D0%BE%D0%B2%D0%B0%D0%BB%D1%8C%D1%81%D1%8C%D0%BA%D0%B0%C2%BB","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":2,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"https://kovalska.com/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"KOVALSKA Industrial-Construction Group","keywords":"","description":" ICG Kovalska - (full name: Association "Industrial and Construction Group" Kovalska ") - Ukrainian manufacturer of building materials and builder. It is a part of Joint Stock Company «Reinforced Concrete Structures Plant. Svetlana Kowalska ”, a","og:title":"KOVALSKA Industrial-Construction Group","og:description":" ICG Kovalska - (full name: Association "Industrial and Construction Group" Kovalska ") - Ukrainian manufacturer of building materials and builder. It is a part of Joint Stock Company «Reinforced Concrete Structures Plant. Svetlana Kowalska ”, a","og:image":"https://old.roi4cio.com/uploads/roi/company/Kovalska.jpg"},"eventUrl":""},"supplier":{"id":201,"title":"IT Solutions Ukraine","logoURL":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg","alias":"it-solutions-ukraine","address":"04050, г. Киев , ул. Студенческая, 3","roles":[],"description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field of IT consulting and information security. Fulfills orders for large commercial and state organizations in all regions of Ukraine.<br />When developing possible solutions for the project, the requirements of the customer and the particular infrastructure of the enterprise are taken into account. After that, solutions are offered based on the hardware and software of the world's leading partner manufacturers: HPE, HP inc., Cisco, Lenovo, NetApp, VMware, Oracle, Huawei, Microsoft, TrueConf, APC, MobileIron, ESET, IBM, Fortinet, Veritas, Dell-emc\r\n<span style=\"font-weight: bold;\">IT-Solutions Services</span><br />IT Infrastructure Solutions:\r\n<ul><li>physical (data storage systems, servers, data transmission and cybersecurity devices, construction of server and data processing centers, SCS, VKS, uninterruptible power supply, personal equipment, peripherals, software)</li></ul>\r\n<ul><li>virtualized (servers, storage, network, desktops)</li></ul>\r\n<ul><li>on information security (network, users, email, information security and security events management)</li></ul>\r\nDesign and implementation of infrastructure services:\r\n<ul><li>backup systems</li></ul>\r\n<ul><li>virtualization</li></ul>\r\n<ul><li>cloud services</li></ul>\r\n<ul><li>IT Service Management (ITSM)</li></ul>\r\n<ul><li>information security</li></ul>\r\n<ul><li>monitoring and control systems</li></ul>\r\nConsulting:\r\n<ul><li>data management (storage, backup, recovery)</li></ul>\r\n<ul><li>IT service continuity</li></ul>\r\n<ul><li>analytics (IT audit, business analytics, vScore - preliminary performance assessment for the implementation of virtualization, dScore - data management performance assessment)</li></ul>\r\n<ul><li>Information Security</li></ul>","companyTypes":[],"products":{},"vendoredProductsCount":2,"suppliedProductsCount":228,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":14,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://it-solutions.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"IT Solutions Ukraine","keywords":"Partner, Solutions, projects, Gold, Silver, Business, Enterprise, VMware","description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:title":"IT Solutions Ukraine","og:description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:image":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":417,"logo":false,"scheme":false,"title":"HPE BladeSystem c7000 Enclosures","vendorVerified":0,"rating":"2.40","implementationsCount":12,"suppliersCount":0,"alias":"hpe-bladesystem-c7000-enclosures","companyTypes":[],"description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.\r\n\r\nWhat's new\r\nUniversal high voltage power solution for reduced Datacenter CAPEX & OPEX - 2650W power supply with a wide ranging input supporting 277VAC & 380VDC - Power input module with APP Saf-D-Grid connectors\r\n<span style=\"font-weight: bold;\">Features</span>\r\nExtending the foundation for Converged Infrastructure\r\nThe HP BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.\r\nWith demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.\r\nHP OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.\r\nWith Onboard Administrator, iLO remote management, and HP OneView you can manage your servers and take complete control regardless of the state of the server operating system.","shortDescription":"The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years. The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":11,"sellingCount":9,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE BladeSystem c7000 Enclosures","keywords":"input, with, power, management, server, Power, storage, Infrastructure","description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i","og:title":"HPE BladeSystem c7000 Enclosures","og:description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i"},"eventUrl":"","translationId":418,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":4826,"logo":false,"scheme":false,"title":"HP ProCurve Switch 5400zl Series","vendorVerified":0,"rating":"0.00","implementationsCount":3,"suppliersCount":0,"alias":"hp-procurve-switch-5400zl-series","companyTypes":[],"description":"The HP ProCurve Switch 5400zl Series consists of the most advanced intelligent switches in the HP ProCurve product line. The 5400zl series includes 6-slot and 12-slot chassis and associated zl modules and bundles. The foundation for all of these switches is a purpose-built, programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security, to be implemented in a scalable yet granular fashion. With 10/100, Gigabit and 10-Gigabit interfaces, integrated PoE+ on 10/100 and 10/100/1000Base-T ports, and a choice of form factors, the 5400zl switches offer excellent investment protection, flexibility, and scalability, as well as ease of deployment, operation, and maintenance.\r\n<span style=\"font-weight: bold;\">Key features</span>\r\n<ul><li>Core, distribution, and advanced access layer</li></ul>\r\n<ul><li>Layer 2 to 4 and intelligent edge feature set</li></ul>\r\n<ul><li>Enterprise-class performance and security</li></ul>\r\n<ul><li>HP ProCurve ONE integrated</li></ul>\r\n<ul><li>Scalable 10/100/1000 and 10-GbE connectivity</li></ul>","shortDescription":"The HP ProCurve Switch 5400zl Series consists of the most advanced intelligent switches in the HP ProCurve product line.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":13,"sellingCount":13,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP ProCurve Switch 5400zl Series","keywords":"","description":"The HP ProCurve Switch 5400zl Series consists of the most advanced intelligent switches in the HP ProCurve product line. The 5400zl series includes 6-slot and 12-slot chassis and associated zl modules and bundles. The foundation for all of these switches is a ","og:title":"HP ProCurve Switch 5400zl Series","og:description":"The HP ProCurve Switch 5400zl Series consists of the most advanced intelligent switches in the HP ProCurve product line. The 5400zl series includes 6-slot and 12-slot chassis and associated zl modules and bundles. The foundation for all of these switches is a "},"eventUrl":"","translationId":4827,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":513,"title":"Networking","alias":"networking","description":" Networking hardware, also known as network equipment or computer networking devices, are electronic devices which are required for communication and interaction between devices on a computer network. Specifically, they mediate data transmission in a computer network. Units which are the last receiver or generate data are called hosts or data terminal equipment.\r\nNetworking devices may include gateways, routers, network bridges, modems, wireless access points, networking cables, line drivers, switches, hubs, and repeaters; and may also include hybrid network devices such as multilayer switches, protocol converters, bridge routers, proxy servers, firewalls, network address translators, multiplexers, network interface controllers, wireless network interface controllers, ISDN terminal adapters and other related hardware.\r\nThe most common kind of networking hardware today is a copper-based Ethernet adapter which is a standard inclusion on most modern computer systems. Wireless networking has become increasingly popular, especially for portable and handheld devices.\r\nOther networking hardware used in computers includes data center equipment (such as file servers, database servers and storage areas), network services (such as DNS, DHCP, email, etc.) as well as devices which assure content delivery.\r\nTaking a wider view, mobile phones, tablet computers and devices associated with the internet of things may also be considered networking hardware. As technology advances and IP-based networks are integrated into building infrastructure and household utilities, network hardware will become an ambiguous term owing to the vastly increasing number of network capable endpoints.","materialsDescription":" <span style=\"font-weight: bold;\">What is network equipment?</span>\r\nNetwork equipment - devices necessary for the operation of a computer network, for example: a router, switch, hub, patch panel, etc. You can distinguish between active and passive network equipment.\r\n<span style=\"font-weight: bold;\">What is an active network equipment?</span>\r\nActive networking equipment is equipment followed by some “smart” feature. That is, a router, switch (switch), etc. are active network equipment.\r\n<span style=\"font-weight: bold;\">What is passive network equipment?</span>\r\nPassive network equipment - equipment not endowed with "intellectual" features. For example - cable system: cable (coaxial and twisted pair (UTP/STP)), plug / socket (RG58, RJ45, RJ11, GG45), repeater (repeater), patch panel, hub (hub), balun (balun) for coaxial cables (RG-58), etc. Also, passive equipment can include mounting cabinets and racks, telecommunication cabinets.\r\n<span style=\"font-weight: bold;\">What are the main network components?</span>\r\nThe main components of the network are workstations, servers, transmission media (cables) and network equipment.\r\n<span style=\"font-weight: bold;\">What are workstations?</span>\r\nWorkstations are network computers where network users implement application tasks.\r\n<span style=\"font-weight: bold;\">What are network servers?</span>\r\nNetwork servers - hardware and software systems that perform the functions of controlling the distribution of network shared resources. A server can be any computer connected to the network on which the resources used by other devices on the local network are located. As the server hardware, fairly powerful computers are used.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Networking.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":6,"title":"Ensure Security and Business Continuity"},{"id":7,"title":"Improve Customer Service"},{"id":8,"title":"Reduce Production Timelines"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":340,"title":"Low quality of customer service"},{"id":370,"title":"No automated business processes"},{"id":392,"title":"Lengthy production timelines"}]}},"categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"},{"id":513,"title":"Networking","alias":"networking","description":" Networking hardware, also known as network equipment or computer networking devices, are electronic devices which are required for communication and interaction between devices on a computer network. Specifically, they mediate data transmission in a computer network. Units which are the last receiver or generate data are called hosts or data terminal equipment.\r\nNetworking devices may include gateways, routers, network bridges, modems, wireless access points, networking cables, line drivers, switches, hubs, and repeaters; and may also include hybrid network devices such as multilayer switches, protocol converters, bridge routers, proxy servers, firewalls, network address translators, multiplexers, network interface controllers, wireless network interface controllers, ISDN terminal adapters and other related hardware.\r\nThe most common kind of networking hardware today is a copper-based Ethernet adapter which is a standard inclusion on most modern computer systems. Wireless networking has become increasingly popular, especially for portable and handheld devices.\r\nOther networking hardware used in computers includes data center equipment (such as file servers, database servers and storage areas), network services (such as DNS, DHCP, email, etc.) as well as devices which assure content delivery.\r\nTaking a wider view, mobile phones, tablet computers and devices associated with the internet of things may also be considered networking hardware. As technology advances and IP-based networks are integrated into building infrastructure and household utilities, network hardware will become an ambiguous term owing to the vastly increasing number of network capable endpoints.","materialsDescription":" <span style=\"font-weight: bold;\">What is network equipment?</span>\r\nNetwork equipment - devices necessary for the operation of a computer network, for example: a router, switch, hub, patch panel, etc. You can distinguish between active and passive network equipment.\r\n<span style=\"font-weight: bold;\">What is an active network equipment?</span>\r\nActive networking equipment is equipment followed by some “smart” feature. That is, a router, switch (switch), etc. are active network equipment.\r\n<span style=\"font-weight: bold;\">What is passive network equipment?</span>\r\nPassive network equipment - equipment not endowed with "intellectual" features. For example - cable system: cable (coaxial and twisted pair (UTP/STP)), plug / socket (RG58, RJ45, RJ11, GG45), repeater (repeater), patch panel, hub (hub), balun (balun) for coaxial cables (RG-58), etc. Also, passive equipment can include mounting cabinets and racks, telecommunication cabinets.\r\n<span style=\"font-weight: bold;\">What are the main network components?</span>\r\nThe main components of the network are workstations, servers, transmission media (cables) and network equipment.\r\n<span style=\"font-weight: bold;\">What are workstations?</span>\r\nWorkstations are network computers where network users implement application tasks.\r\n<span style=\"font-weight: bold;\">What are network servers?</span>\r\nNetwork servers - hardware and software systems that perform the functions of controlling the distribution of network shared resources. A server can be any computer connected to the network on which the resources used by other devices on the local network are located. As the server hardware, fairly powerful computers are used.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Networking.png"}],"additionalInfo":{"budgetNotExceeded":"","functionallyTaskAssignment":"","projectWasPut":"","price":0,"source":{"url":"https://it-solutions.ua/portfolio/kovalskaya/","title":"Supplier's web site"}},"comments":[],"referencesCount":0},"hp-proliant-bl-hp-eva-storage-hpe-bladesystem-c7000-oilfield-enclosures":{"id":67,"title":"HP ProLiant BL, HP EVA Storage, HPE BladeSystem c7000 Oilfield Enclosures","description":"Description is not ready yet","alias":"hp-proliant-bl-hp-eva-storage-hpe-bladesystem-c7000-oilfield-enclosures","roi":0,"seo":{"title":"HP ProLiant BL, HP EVA Storage, HPE BladeSystem c7000 Oilfield Enclosures","keywords":"","description":"Description is not ready yet","og:title":"HP ProLiant BL, HP EVA Storage, HPE BladeSystem c7000 Oilfield Enclosures","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":2919,"title":"Ukrnafta","logoURL":"https://old.roi4cio.com/uploads/roi/company/ukrnafta.png","alias":"ukrnafta","address":"","roles":[],"description":"Ukrnafta is the largest oil company in Ukraine. The company’s share in the nation’s oil and gas condensate production in 2015 is 67,9%, while the share in total gas production is 7,6%.\r\nAs of 31 December 2015, PJSC «Ukrnafta» had 82 permits for hydrocarbons extraction (commercial development of reserves).\r\nUkrnafta’s drilling divisions cumulatively own 58 drilling rigs.\r\nUkrnafta owns one of the largest filling stations network in Ukraine in almost every region of Ukraine. As of 31 December 2015, PJSC «Ukrnafta» had 537 filling stations.\r\nUkrnafta is headquartered in Kyiv, Ukraine’s capital. The company is 50%+1 share owned by Naftogaz of Ukraine, a fully state-owned holding company.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":2,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://www.ukrnafta.com/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Ukrnafta","keywords":"Ukrnafta, Ukraine, share, 2015, company, drilling, December, PJSC","description":"Ukrnafta is the largest oil company in Ukraine. The company’s share in the nation’s oil and gas condensate production in 2015 is 67,9%, while the share in total gas production is 7,6%.\r\nAs of 31 December 2015, PJSC «Ukrnafta» had 82 permits for hydrocarbons ex","og:title":"Ukrnafta","og:description":"Ukrnafta is the largest oil company in Ukraine. The company’s share in the nation’s oil and gas condensate production in 2015 is 67,9%, while the share in total gas production is 7,6%.\r\nAs of 31 December 2015, PJSC «Ukrnafta» had 82 permits for hydrocarbons ex","og:image":"https://old.roi4cio.com/uploads/roi/company/ukrnafta.png"},"eventUrl":""},"supplier":{"id":201,"title":"IT Solutions Ukraine","logoURL":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg","alias":"it-solutions-ukraine","address":"04050, г. Киев , ул. Студенческая, 3","roles":[],"description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field of IT consulting and information security. Fulfills orders for large commercial and state organizations in all regions of Ukraine.<br />When developing possible solutions for the project, the requirements of the customer and the particular infrastructure of the enterprise are taken into account. After that, solutions are offered based on the hardware and software of the world's leading partner manufacturers: HPE, HP inc., Cisco, Lenovo, NetApp, VMware, Oracle, Huawei, Microsoft, TrueConf, APC, MobileIron, ESET, IBM, Fortinet, Veritas, Dell-emc\r\n<span style=\"font-weight: bold;\">IT-Solutions Services</span><br />IT Infrastructure Solutions:\r\n<ul><li>physical (data storage systems, servers, data transmission and cybersecurity devices, construction of server and data processing centers, SCS, VKS, uninterruptible power supply, personal equipment, peripherals, software)</li></ul>\r\n<ul><li>virtualized (servers, storage, network, desktops)</li></ul>\r\n<ul><li>on information security (network, users, email, information security and security events management)</li></ul>\r\nDesign and implementation of infrastructure services:\r\n<ul><li>backup systems</li></ul>\r\n<ul><li>virtualization</li></ul>\r\n<ul><li>cloud services</li></ul>\r\n<ul><li>IT Service Management (ITSM)</li></ul>\r\n<ul><li>information security</li></ul>\r\n<ul><li>monitoring and control systems</li></ul>\r\nConsulting:\r\n<ul><li>data management (storage, backup, recovery)</li></ul>\r\n<ul><li>IT service continuity</li></ul>\r\n<ul><li>analytics (IT audit, business analytics, vScore - preliminary performance assessment for the implementation of virtualization, dScore - data management performance assessment)</li></ul>\r\n<ul><li>Information Security</li></ul>","companyTypes":[],"products":{},"vendoredProductsCount":2,"suppliedProductsCount":228,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":14,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://it-solutions.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"IT Solutions Ukraine","keywords":"Partner, Solutions, projects, Gold, Silver, Business, Enterprise, VMware","description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:title":"IT Solutions Ukraine","og:description":"IT-Solutions has established itself as an experienced IT integrator, reliable partner and supplier.<br />IT-Solutions is an expert in virtualization, management and data storage. Implements modern solutions for IT infrastructure, provides services in the field","og:image":"https://old.roi4cio.com/uploads/roi/company/IT_Solutions.jpg"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":417,"logo":false,"scheme":false,"title":"HPE BladeSystem c7000 Enclosures","vendorVerified":0,"rating":"2.40","implementationsCount":12,"suppliersCount":0,"alias":"hpe-bladesystem-c7000-enclosures","companyTypes":[],"description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.\r\n\r\nWhat's new\r\nUniversal high voltage power solution for reduced Datacenter CAPEX & OPEX - 2650W power supply with a wide ranging input supporting 277VAC & 380VDC - Power input module with APP Saf-D-Grid connectors\r\n<span style=\"font-weight: bold;\">Features</span>\r\nExtending the foundation for Converged Infrastructure\r\nThe HP BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.\r\nWith demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.\r\nHP OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.\r\nWith Onboard Administrator, iLO remote management, and HP OneView you can manage your servers and take complete control regardless of the state of the server operating system.","shortDescription":"The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years. The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":11,"sellingCount":9,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE BladeSystem c7000 Enclosures","keywords":"input, with, power, management, server, Power, storage, Infrastructure","description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i","og:title":"HPE BladeSystem c7000 Enclosures","og:description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i"},"eventUrl":"","translationId":418,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":419,"logo":false,"scheme":false,"title":"HP EVA Storage","vendorVerified":0,"rating":"2.00","implementationsCount":9,"suppliersCount":0,"alias":"hp-eva-storage","companyTypes":[],"description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, mid-sized organizations count on HP EVA Storage. This fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.\r\n\r\nFor medium-sized companies:\r\nDecrease storage management cost by 20-30%.1\r\nBalance price and performance with dynamic storage tiering and non-disruptive data migration.","shortDescription":"HP EVA Storage - fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":18,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP EVA Storage","keywords":"storage, data, while, availability, Storage, increasing, organizations, productivity","description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m","og:title":"HP EVA Storage","og:description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m"},"eventUrl":"","translationId":420,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":6,"title":"Ensure Security and Business Continuity"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":175,"title":"Aging IT infrastructure"}]}},"categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"},{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"","functionallyTaskAssignment":"","projectWasPut":"","price":0,"source":{"url":"http://it-solutions.ua/ru/c49-ukrnafta.html","title":"Supplier's web site"}},"comments":[],"referencesCount":0},"hp-proliant-bl-hp-proliant-bl-hp-eva-for-ecomarket-chain":{"id":944,"title":"HP ProLiant BL, HP ProLiant BL, HP EVA for ECOMARKET chain","description":"Description is not ready yet","alias":"hp-proliant-bl-hp-proliant-bl-hp-eva-for-ecomarket-chain","roi":0,"seo":{"title":"HP ProLiant BL, HP ProLiant BL, HP EVA for ECOMARKET chain","keywords":"","description":"Description is not ready yet","og:title":"HP ProLiant BL, HP ProLiant BL, HP EVA for ECOMARKET chain","og:description":"Description is not ready yet"},"deal_info":"","user":{"id":7350,"title":"EKO market","logoURL":"https://old.roi4cio.com/uploads/roi/company/ekomarket.jpg","alias":"ehko-market","address":"","roles":[],"description":" The all-Ukrainian supermarket chain ECO Market currently has 114 stores in 34 cities of Ukraine. The company employs more than 9,000 thousand people. The network presents food products, household chemicals, essential goods. It also has its own production - cooking and bakeries, some shops have their own confectionery shops.<br />The history of the company began in 2003, when the first EKO market grocery supermarket was opened in Chernigov. In the same year, supermarkets were opened in Sumy, Zaporozhye, Kremenchug, Odessa and Cherkasy. Already in 2004, the number of supermarkets in the chain grew to 18. In 2006, there were 28 ECO chain stores in Ukraine; and in 2010 - 68.<br />In 2015, according to GT Partners, ECO Market took 4th place in the TOP 5 of the largest retail chains in Ukraine.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":0,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":1,"supplierImplementationsCount":0,"vendorImplementationsCount":0,"vendorPartnersCount":0,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"https://www.eko.com.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"EKO market","keywords":"","description":" The all-Ukrainian supermarket chain ECO Market currently has 114 stores in 34 cities of Ukraine. The company employs more than 9,000 thousand people. The network presents food products, household chemicals, essential goods. It also has its own production - co","og:title":"EKO market","og:description":" The all-Ukrainian supermarket chain ECO Market currently has 114 stores in 34 cities of Ukraine. The company employs more than 9,000 thousand people. The network presents food products, household chemicals, essential goods. It also has its own production - co","og:image":"https://old.roi4cio.com/uploads/roi/company/ekomarket.jpg"},"eventUrl":""},"supplier":{"id":249,"title":"Integrity Systems","logoURL":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png","alias":"integrity-systems","address":"Київ 01032 вул. Саксаганського, 119, оф. 26","roles":[],"description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its activities on solutions using various technologies IT business objectives corporate customers in Ukraine. The main asset is our team of qualified consultants, project managers and engineers, allowing us to offer our clients services that cover the full life cycle of IT solutions - from analyzing business objectives, design, implementation and further maintenance and support.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":197,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":9,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://integritysys.com.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Integrity Systems","keywords":"Systems, solutions, Integrity, implementation, design, company, business, objectives","description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:title":"Integrity Systems","og:description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:image":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":47,"logo":false,"scheme":false,"title":"HPE ProLiant DL Rack","vendorVerified":0,"rating":"2.00","implementationsCount":1,"suppliersCount":0,"alias":"hpe-proliant-dl-rack","companyTypes":[],"description":"The DL family of servers are the most flexible, reliable, and performance-optimized ProLiant rack servers—ever. HPE continues to provide industry-leading compute innovations, the new HPE ProLiant Gen10 rack portfolio, with flexible choices and versatile design, along with improved energy efficiencies, ultimately lowers your TCO. Integrated with a simplified, but comprehensive management suite and industry-leading support, the ProLiant Gen10 rack portfolio delivers a more reliable, fast, and secure infrastructure solution, helps increase IT staff productivity, and accelerates service delivery. In addition, the rack portfolio is performance-optimized for multi-application workloads to significantly increase the speed of IT operations and enable IT to respond to business needs of any size, faster. The HPE ProLiant Gen10 rack portfolio delivers:\r\n<ul> <li>Up to 71% performance increase and 27% increase in core with the new Intel Xeon Scalable processors</li> <li>Up to 27X faster checkpoint operations enabling significantly faster business operations</li> <li>66% greater memory bandwidth increasing application performance for memory-intensive applications</li> <li>14% more processor cores for greater VM density and 33% greater memory capacity for better VM performance and price/performance using AMD EPYC processors</li> </ul>\r\nThe HPE ProLiant Gen9 rack portfolio delivers the right compute for the right workload at the right economics - every time. They are built to excel for any size business, for any size workload, in any environment with:\r\n<ul> <li>66X faster service delivery with simple automation, saving admin time, and reducing errors from manual steps</li> <li>4X faster workload performance to transform the business, growing revenue, margin, and share</li> </ul>","shortDescription":"ProLiant Servers provide a complete infrastructure that support both your business objectives and your business growth.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":0,"sellingCount":18,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant DL Rack","keywords":"your, ProLiant, business, both, objectives, growth, support, that","description":"The DL family of servers are the most flexible, reliable, and performance-optimized ProLiant rack servers—ever. HPE continues to provide industry-leading compute innovations, the new HPE ProLiant Gen10 rack portfolio, with flexible choices and versatile design","og:title":"HPE ProLiant DL Rack","og:description":"The DL family of servers are the most flexible, reliable, and performance-optimized ProLiant rack servers—ever. HPE continues to provide industry-leading compute innovations, the new HPE ProLiant Gen10 rack portfolio, with flexible choices and versatile design"},"eventUrl":"","translationId":104,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":419,"logo":false,"scheme":false,"title":"HP EVA Storage","vendorVerified":0,"rating":"2.00","implementationsCount":9,"suppliersCount":0,"alias":"hp-eva-storage","companyTypes":[],"description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, mid-sized organizations count on HP EVA Storage. This fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.\r\n\r\nFor medium-sized companies:\r\nDecrease storage management cost by 20-30%.1\r\nBalance price and performance with dynamic storage tiering and non-disruptive data migration.","shortDescription":"HP EVA Storage - fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":18,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP EVA Storage","keywords":"storage, data, while, availability, Storage, increasing, organizations, productivity","description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m","og:title":"HP EVA Storage","og:description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m"},"eventUrl":"","translationId":420,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":4,"title":"Reduce Costs"},{"id":6,"title":"Ensure Security and Business Continuity"},{"id":306,"title":"Manage Risks"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":178,"title":"No control over data access"},{"id":342,"title":"Total high cost of ownership of IT infrastructure (TCO)"},{"id":348,"title":"No centralized control over IT systems"},{"id":370,"title":"No automated business processes"},{"id":374,"title":"IT infrastructure downtimes"},{"id":386,"title":"Risk of lost access to data and IT systems"}]}},"categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"},{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"additionalInfo":{"budgetNotExceeded":"-1","functionallyTaskAssignment":"-1","projectWasPut":"-1","price":0,"source":{"url":"https://ko.com.ua/eko-market_nachnet_s_chistogo_lista_53686","title":"Media"}},"comments":[],"referencesCount":0},"hpe-bladesystems-c7000-hp-eva-hp-proliant-bl-for-sportmaster-network":{"id":943,"title":"HPE BladeSystems c7000, HP EVA, HP ProLiant BL for Sportmaster network","description":"Description is not ready yet","alias":"hpe-bladesystems-c7000-hp-eva-hp-proliant-bl-for-sportmaster-network","roi":0,"seo":{"title":"HPE BladeSystems c7000, HP EVA, HP ProLiant BL for Sportmaster network","keywords":"","description":"Description is not ready yet","og:title":"HPE BladeSystems c7000, HP EVA, HP ProLiant BL for Sportmaster network","og:description":"Description is not ready yet"},"deal_info":"","user":{},"supplier":{"id":249,"title":"Integrity Systems","logoURL":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png","alias":"integrity-systems","address":"Київ 01032 вул. Саксаганського, 119, оф. 26","roles":[],"description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its activities on solutions using various technologies IT business objectives corporate customers in Ukraine. The main asset is our team of qualified consultants, project managers and engineers, allowing us to offer our clients services that cover the full life cycle of IT solutions - from analyzing business objectives, design, implementation and further maintenance and support.","companyTypes":[],"products":{},"vendoredProductsCount":0,"suppliedProductsCount":197,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":15,"vendorImplementationsCount":0,"vendorPartnersCount":9,"supplierPartnersCount":0,"b4r":0,"categories":{},"companyUrl":"http://integritysys.com.ua/","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Integrity Systems","keywords":"Systems, solutions, Integrity, implementation, design, company, business, objectives","description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:title":"Integrity Systems","og:description":"Integrity Systems is a young company, system integrator dynamic. Integrity Systems specializes in the design and implementation of IT solutions for medium and large enterprises. The company "Systems Integration" was founded in 2007 and focuses its ac","og:image":"https://old.roi4cio.com/uploads/roi/company/integrity_systems.png"},"eventUrl":""},"vendors":[{"id":172,"title":"Hewlett Packard Enterprise","logoURL":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg","alias":"hewlett-packard-enterprise","address":"","roles":[],"description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is a business-focused organization with two divisions: Enterprise Group, which works in servers, storage, networking, consulting and support, and Financial Services. On 4 December HPE reported FY2018 net revenue of $30.9 billion, up 7% from the prior year period.","companyTypes":[],"products":{},"vendoredProductsCount":19,"suppliedProductsCount":19,"supplierImplementations":[],"vendorImplementations":[],"userImplementations":[],"userImplementationsCount":0,"supplierImplementationsCount":0,"vendorImplementationsCount":26,"vendorPartnersCount":0,"supplierPartnersCount":452,"b4r":0,"categories":{},"companyUrl":"www.hpe.com","countryCodes":[],"certifications":[],"isSeller":false,"isSupplier":false,"isVendor":false,"presenterCodeLng":"","seo":{"title":"Hewlett Packard Enterprise","keywords":"Packard, Hewlett, Enterprise, company, 2015, November, Hewlett-Packard, now-split","description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:title":"Hewlett Packard Enterprise","og:description":"The Hewlett Packard Enterprise Company (commonly referred to as HPE) is an American multinational enterprise information technology company based in San Jose, California,[2] founded on 1 November 2015 as part of splitting of the Hewlett-Packard company. HPE is","og:image":"https://old.roi4cio.com/uploads/roi/company/HPE_logo.jpeg"},"eventUrl":""}],"products":[{"id":417,"logo":false,"scheme":false,"title":"HPE BladeSystem c7000 Enclosures","vendorVerified":0,"rating":"2.40","implementationsCount":12,"suppliersCount":0,"alias":"hpe-bladesystem-c7000-enclosures","companyTypes":[],"description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.\r\n\r\nWhat's new\r\nUniversal high voltage power solution for reduced Datacenter CAPEX & OPEX - 2650W power supply with a wide ranging input supporting 277VAC & 380VDC - Power input module with APP Saf-D-Grid connectors\r\n<span style=\"font-weight: bold;\">Features</span>\r\nExtending the foundation for Converged Infrastructure\r\nThe HP BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.\r\nWith demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.\r\nHP OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.\r\nWith Onboard Administrator, iLO remote management, and HP OneView you can manage your servers and take complete control regardless of the state of the server operating system.","shortDescription":"The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years. The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":11,"sellingCount":9,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE BladeSystem c7000 Enclosures","keywords":"input, with, power, management, server, Power, storage, Infrastructure","description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i","og:title":"HPE BladeSystem c7000 Enclosures","og:description":"It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC i"},"eventUrl":"","translationId":418,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":419,"logo":false,"scheme":false,"title":"HP EVA Storage","vendorVerified":0,"rating":"2.00","implementationsCount":9,"suppliersCount":0,"alias":"hp-eva-storage","companyTypes":[],"description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, mid-sized organizations count on HP EVA Storage. This fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.\r\n\r\nFor medium-sized companies:\r\nDecrease storage management cost by 20-30%.1\r\nBalance price and performance with dynamic storage tiering and non-disruptive data migration.","shortDescription":"HP EVA Storage - fifth-generation, virtualized storage array provides availability while increasing productivity and capacity utilization.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":18,"sellingCount":12,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HP EVA Storage","keywords":"storage, data, while, availability, Storage, increasing, organizations, productivity","description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m","og:title":"HP EVA Storage","og:description":"Overview\r\nEVA_Page\r\nLean IT budgets require more efficient ways of managing data. Driving business growth and agility requires simple yet flexible storage that reduces costs while maintaining application availability.\r\nWith an installed base of over 100,000, m"},"eventUrl":"","translationId":420,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]},{"id":421,"logo":false,"scheme":false,"title":"HPE ProLiant BL Server Blade","vendorVerified":0,"rating":"2.00","implementationsCount":10,"suppliersCount":0,"alias":"hpe-proliant-bl-server-blade","companyTypes":[],"description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal solution for enterprises and service providers with limited space.\r\n","shortDescription":"HPE ProLiant BL Server Blade with the latest dual-core processors have the same features, capabilities and benefits of rack servers, consuming less energy and are more efficient to use.","type":null,"isRoiCalculatorAvaliable":false,"isConfiguratorAvaliable":false,"bonus":100,"usingCount":12,"sellingCount":0,"discontinued":0,"rebateForPoc":0,"rebate":0,"seo":{"title":"HPE ProLiant BL Server Blade","keywords":"Blade, ProLiant, Server, ideal, roles, server, changing, solution","description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s","og:title":"HPE ProLiant BL Server Blade","og:description":"HPE ProLiant BL Server Blade allow you to choose the type of connection and storage.\r\n<span style=\"font-weight: bold; \">Benefits:</span>\r\n- HPE ProLiant BL Server Blade are compact and optimized for rapid deployment and changing of server roles;\r\n- The ideal s"},"eventUrl":"","translationId":422,"dealDetails":null,"roi":null,"price":null,"bonusForReference":null,"templateData":[],"testingArea":"","categories":[{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"characteristics":[],"concurentProducts":[],"jobRoles":[],"organizationalFeatures":[],"complementaryCategories":[],"solutions":[],"materials":[],"useCases":[],"best_practices":[],"values":[],"implementations":[]}],"countries":[{"id":217,"title":"Ukraine","name":"UKR"}],"startDate":"0000-00-00","endDate":"0000-00-00","dealDate":"0000-00-00","price":0,"status":"finished","statusLabel":"Finished","isImplementation":true,"isAgreement":false,"confirmed":1,"implementationDetails":{"businessObjectives":{"id":14,"title":"Business objectives","translationKey":"businessObjectives","options":[{"id":4,"title":"Reduce Costs"},{"id":6,"title":"Ensure Security and Business Continuity"},{"id":7,"title":"Improve Customer Service"},{"id":9,"title":"Support Decision Making"},{"id":10,"title":"Ensure Compliance"},{"id":254,"title":"Centralize management"},{"id":306,"title":"Manage Risks"}]},"businessProcesses":{"id":11,"title":"Business process","translationKey":"businessProcesses","options":[{"id":177,"title":"Decentralized IT systems"},{"id":334,"title":"Poor timing of management decision making"},{"id":366,"title":"IT infrastructure consumes a lot of power"},{"id":386,"title":"Risk of lost access to data and IT systems"},{"id":387,"title":"Non-compliant with IT security requirements"},{"id":400,"title":"High costs"}]}},"categories":[{"id":517,"title":"Blade System","alias":"blade-system","description":" A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, while still having all the functional components to be considered a computer. Unlike a rack-mount server, a blade server needs a blade enclosure, which can hold multiple blade servers, providing services such as power, cooling, networking, various interconnects and management. Together, blades and the blade enclosure form a blade system. Different blade providers have differing principles regarding what to include in the blade itself, and in the blade system as a whole.\r\nIn a standard server-rack configuration, one rack unit or 1U—19 inches (480 mm) wide and 1.75 inches (44 mm) tall—defines the minimum possible size of any equipment. The principal benefit and justification of blade computing relates to lifting this restriction so as to reduce size requirements. The most common computer rack form-factor is 42U high, which limits the number of discrete computer devices directly mountable in a rack to 42 components. Blades do not have this limitation. As of 2014, densities of up to 180 servers per blade system (or 1440 servers per rack) are achievable with blade systems.\r\nEnclosure (or chassis) performs many of the non-core computing services found in most computers. Non-blade systems typically use bulky, hot and space-inefficient components, and may duplicate these across many computers that may or may not perform at capacity. By locating these services in one place and sharing them among the blade computers, the overall utilization becomes higher. The specifics of which services are provided varies by vendor.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Power.</span></span> Computers operate over a range of DC voltages, but utilities deliver power as AC, and at higher voltages than required within computers. Converting this current requires one or more power supply units (or PSUs). To ensure that the failure of one power source does not affect the operation of the computer, even entry-level servers may have redundant power supplies, again adding to the bulk and heat output of the design.\r\nThe blade enclosure's power supply provides a single power source for all blades within the enclosure. This single power source may come as a power supply in the enclosure or as a dedicated separate PSU supplying DC to multiple enclosures. This setup reduces the number of PSUs required to provide a resilient power supply.\r\nThe popularity of blade servers, and their own appetite for power, has led to an increase in the number of rack-mountable uninterruptible power supply (or UPS) units, including units targeted specifically towards blade servers (such as the BladeUPS).\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Cooling.</span></span> During operation, electrical and mechanical components produce heat, which a system must dissipate to ensure the proper functioning of its components. Most blade enclosures, like most computing systems, remove heat by using fans.\r\nA frequently underestimated problem when designing high-performance computer systems involves the conflict between the amount of heat a system generates and the ability of its fans to remove the heat. The blade's shared power and cooling means that it does not generate as much heat as traditional servers. Newer blade-enclosures feature variable-speed fans and control logic, or even liquid cooling systems that adjust to meet the system's cooling requirements.\r\nAt the same time, the increased density of blade-server configurations can still result in higher overall demands for cooling with racks populated at over 50% full. This is especially true with early-generation blades. In absolute terms, a fully populated rack of blade servers is likely to require more cooling capacity than a fully populated rack of standard 1U servers. This is because one can fit up to 128 blade servers in the same rack that will only hold 42 1U rack mount servers.\r\n<span style=\"font-style: italic; \"><span style=\"font-weight: bold; \">Networking.</span></span> Blade servers generally include integrated or optional network interface controllers for Ethernet or host adapters for Fibre Channel storage systems or converged network adapter to combine storage and data via one Fibre Channel over Ethernet interface. In many blades at least one interface is embedded on the motherboard and extra interfaces can be added using mezzanine cards.\r\nA blade enclosure can provide individual external ports to which each network interface on a blade will connect. Alternatively, a blade enclosure can aggregate network interfaces into interconnect devices (such as switches) built into the blade enclosure or in networking blades.\r\nBlade servers function well for specific purposes such as web hosting, virtualization, and cluster computing. Individual blades are typically hot-swappable. As users deal with larger and more diverse workloads, they add more processing power, memory and I/O bandwidth to blade servers. Although blade server technology in theory allows for open, cross-vendor system, most users buy modules, enclosures, racks and management tools from the same vendor.\r\nEventual standardization of the technology might result in more choices for consumers; as of 2009 increasing numbers of third-party software vendors have started to enter this growing field.\r\nBlade servers do not, however, provide the answer to every computing problem. One can view them as a form of productized server-farm that borrows from mainframe packaging, cooling, and power-supply technology. Very large computing tasks may still require server farms of blade servers, and because of blade servers' high power density, can suffer even more acutely from the heating, ventilation, and air conditioning problems that affect large conventional server farms.","materialsDescription":" <span style=\"font-weight: bold;\">What is blade server?</span>\r\nA blade server is a server chassis housing multiple thin, modular electronic circuit boards, known as server blades. Each blade is a server in its own right, often dedicated to a single application. The blades are literally servers on a card, containing processors, memory, integrated network controllers, an optional Fiber Channel host bus adaptor (HBA) and other input/output (IO) ports.\r\nBlade servers allow more processing power in less rack space, simplifying cabling and reducing power consumption. According to a SearchWinSystems.com article on server technology, enterprises moving to blade servers can experience as much as an 85% reduction in cabling for blade installations over conventional 1U or tower servers. With so much less cabling, IT administrators can spend less time managing the infrastructure and more time ensuring high availability.\r\nEach blade typically comes with one or two local ATA or SCSI drives. For additional storage, blade servers can connect to a storage pool facilitated by a network-attached storage (NAS), Fiber Channel, or iSCSI storage-area network (SAN). The advantage of blade servers comes not only from the consolidation benefits of housing several servers in a single chassis, but also from the consolidation of associated resources (like storage and networking equipment) into a smaller architecture that can be managed through a single interface.\r\nA blade server is sometimes referred to as a high-density server and is typically used in a clustering of servers that are dedicated to a single task, such as:\r\n<ul><li>File sharing</li><li>Web page serving and caching</li><li>SSL encrypting of Web communication</li><li>The transcoding of Web page content for smaller displays</li><li>Streaming audio and video content</li></ul>\r\nLike most clustering applications, blade servers can also be managed to include load balancing and failover capabilities.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Blade_System.png"},{"id":7,"title":"Storage - General-Purpose Disk Arrays","alias":"storage-general-purpose-disk-arrays","description":" General-purpose disk arrays refer to disk storage systems that work together with specialized array controllers to achieve high data transfer. They are designed to fulfill the requirement of a diverse set of workloads such as databases, virtual desktop infrastructure, and virtual networks. The market size in the study represents the revenue generated through various deployment modes such as NAS, SAN, and DAS. Some of the technologies used in the general-purpose disk arrays market include PATA, SATA, and SCSI. The application areas of general-purpose disk arrays include BFSI, IT, government, education & research, healthcare, and manufacturing.\r\nGeneral-Purpose Disk Arrays market in BFSI accounts for the largest revenue. IT industry and governments are investing heavily in the general-purpose disk arrays, as a huge amount of voluminous data is getting generated which requires high storage capacity to store the classified data for analytics purpose and consumer insights. General-Purpose Disk Arrays market in healthcare is expected to show robust growth during the forecast period, as hospitals are adopting the latest technology with huge storage spaces in an attempt to track the patient history for providing better healthcare facilities.\r\nThe global general-purpose disk arrays market is fragmented owing to the presence of a large number of local and regional players, which intensifies the degree of rivalry. The market is growing at a notable pace, which leads to high intensity of rivalry. Key market players such as Dell EMC, HPE, and IBM Corporation seek to gain market share through continuous innovations in storage technology. Some of the other key players operating in a market are Hitachi, Seagate Technologies, NetApp, Promise Technologies, Quantum Corporation, Oracle Corporation, Fujitsu, DataDirect Networks, and Infortrend Technology Inc. Key competitors are specifically focusing on Asia-Pacific and Middle-East & Africa regions, as they show strong tendency to adopt the general-purpose disk arrays in coming years.","materialsDescription":"<span style=\"font-weight: bold;\">What are the characteristics of storage?</span>\r\nStorage technologies at all levels of the storage hierarchy can be differentiated by evaluating certain core characteristics as well as measuring characteristics specific to a particular implementation. These core characteristics are volatility, mutability, accessibility, and addressability. For any particular implementation of any storage technology, the characteristics worth measuring are capacity and performance.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Volatility</span></span>\r\nNon-volatile memory retains the stored information even if not constantly supplied with electric power. It is suitable for long-term storage of information. Volatile memory requires constant power to maintain the stored information. The fastest memory technologies are volatile ones, although that is not a universal rule. Since the primary storage is required to be very fast, it predominantly uses volatile memory.\r\nDynamic random-access memory is a form of volatile memory that also requires the stored information to be periodically reread and rewritten, or refreshed, otherwise it would vanish. Static random-access memory is a form of volatile memory similar to DRAM with the exception that it never needs to be refreshed as long as power is applied; it loses its content when the power supply is lost.\r\nAn uninterruptible power supply (UPS) can be used to give a computer a brief window of time to move information from primary volatile storage into non-volatile storage before the batteries are exhausted. Some systems, for example EMC Symmetrix, have integrated batteries that maintain volatile storage for several minutes.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Mutability</span></span>\r\n<span style=\"font-weight: bold;\">Read/write storage or mutable storage</span>\r\n<div class=\"indent\">Allows information to be overwritten at any time. A computer without some amount of read/write storage for primary storage purposes would be useless for many tasks. Modern computers typically use read/write storage also for secondary storage.</div>\r\n<span style=\"font-weight: bold;\">Slow write, fast read storage</span>\r\n<div class=\"indent\">Read/write storage which allows information to be overwritten multiple times, but with the write operation being much slower than the read operation. Examples include CD-RW and SSD.</div>\r\n<span style=\"font-weight: bold;\">Write once storage</span>\r\n<div class=\"indent\">Write Once Read Many (WORM) allows the information to be written only once at some point after manufacture. Examples include semiconductor programmable read-only memory and CD-R.</div>\r\n<span style=\"font-weight: bold;\">Read only storage</span>\r\n<div class=\"indent\">Retains the information stored at the time of manufacture. Examples include mask ROM ICs and CD-ROM.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Accessibility</span></span>\r\n<span style=\"font-weight: bold;\">Random access</span>\r\n<div class=\"indent\">Any location in storage can be accessed at any moment in approximately the same amount of time. Such characteristic is well suited for primary and secondary storage. Most semiconductor memories and disk drives provide random access.</div>\r\n<span style=\"font-weight: bold;\">Sequential access</span>\r\n<div class=\"indent\">The accessing of pieces of information will be in a serial order, one after the other; therefore the time to access a particular piece of information depends upon which piece of information was last accessed. Such characteristic is typical of off-line storage.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Addressability</span></span>\r\n<span style=\"font-weight: bold;\">Location-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information in storage is selected with its numerical memory address. In modern computers, location-addressable storage usually limits to primary storage, accessed internally by computer programs, since location-addressability is very efficient, but burdensome for humans.</div>\r\n<span style=\"font-weight: bold;\">File addressable</span>\r\n<div class=\"indent\">Information is divided into files of variable length, and a particular file is selected with human-readable directory and file names. The underlying device is still location-addressable, but the operating system of a computer provides the file system abstraction to make the operation more understandable. In modern computers, secondary, tertiary and off-line storage use file systems.</div>\r\n<span style=\"font-weight: bold;\">Content-addressable</span>\r\n<div class=\"indent\">Each individually accessible unit of information is selected based on the basis of (part of) the contents stored there. Content-addressable storage can be implemented using software (computer program) or hardware (computer device), with hardware being faster but more expensive option. Hardware content addressable memory is often used in a computer's CPU cache.</div>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Capacity</span></span>\r\n<span style=\"font-weight: bold;\">Raw capacity</span>\r\n<div class=\"indent\">The total amount of stored information that a storage device or medium can hold. It is expressed as a quantity of bits or bytes (e.g. 10.4 megabytes).</div>\r\n<span style=\"font-weight: bold;\">Memory storage density</span>\r\n<div class=\"indent\">The compactness of stored information. It is the storage capacity of a medium divided with a unit of length, area or volume (e.g. 1.2 megabytes per square inch).</div>\r\n\r\n<span style=\"font-weight: bold;\"><span style=\"font-style: italic;\">Performance</span></span>\r\n<span style=\"font-weight: bold;\">Latency</span>\r\n<div class=\"indent\">The time it takes to access a particular location in storage. The relevant unit of measurement is typically nanosecond for primary storage, millisecond for secondary storage, and second for tertiary storage. It may make sense to separate read latency and write latency (especially for non-volatile memory[8]) and in case of sequential access storage, minimum, maximum and average latency.</div>\r\n<span style=\"font-weight: bold;\">Throughput</span>\r\n<div class=\"indent\">The rate at which information can be read from or written to the storage. In computer data storage, throughput is usually expressed in terms of megabytes per second (MB/s), though bit rate may also be used. As with latency, read rate and write rate may need to be differentiated. Also accessing media sequentially, as opposed to randomly, typically yields maximum throughput.</div>\r\n<span style=\"font-weight: bold;\">Granularity</span>\r\n<div class=\"indent\">The size of the largest "chunk" of data that can be efficiently accessed as a single unit, e.g. without introducing additional latency.</div>\r\n<span style=\"font-weight: bold;\">Reliability</span>\r\n<div class=\"indent\">The probability of spontaneous bit value change under various conditions, or overall failure rate.</div>\r\nUtilities such as hdparm and sar can be used to measure IO performance in Linux.\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Energy use</span></span>\r\n<ul><li>Storage devices that reduce fan usage, automatically shut-down during inactivity, and low power hard drives can reduce energy consumption by 90 percent.</li><li>2.5-inch hard disk drives often consume less power than larger ones. Low capacity solid-state drives have no moving parts and consume less power than hard disks. Also, memory may use more power than hard disks. Large caches, which are used to avoid hitting the memory wall, may also consume a large amount of power.</li></ul>\r\n\r\n<span style=\"font-style: italic;\"><span style=\"font-weight: bold;\">Security</span></span>\r\nFull disk encryption, volume and virtual disk encryption, andor file/folder encryption is readily available for most storage devices.\r\nHardware memory encryption is available in Intel Architecture, supporting Total Memory Encryption (TME) and page granular memory encryption with multiple keys (MKTME) and in SPARC M7 generation since October 2015.","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Storage_General_Purpose_Disk_Arrays.png"},{"id":435,"title":"Rack Server","alias":"rack-server","description":"A rack mount server is a great way to maximize your shelf space by packing a lot of servers into a small space. Rackmount servers are typically easier for administrators to manage due to proximity, modularity and better cable management. Lockable rack cabinet doors and steel server front panels provide an additional level of physical security. Additionally, rack unit designed servers are better able to keep the server components cool than traditional tower form factor. Industry standard 19-inch racks will allow you to easily expand your business without taking up more valuable floor space.\r\nThere is a lot of thought that needs to go into which size rack server is best bet for your project. Both current requirements and future expansion plans need to be taken into account to ensure your server remains capable in the future.\r\nBoth large and small projects can be built on the 1U server platform. "U" stands for unit, “unit”, and this means thickness: server rack 1U = 1.75 inches or 44 mm wide. A reasonable amount of storage can fit within a 1U, processing power has no limits, and some models even allow up to two PCI-Express cards. Modern computer hardware uses much less power than it ever has in the past, which means less heat generation. Some 1U servers to still produce some acoustic noise, but is nowhere near the level of needing earmuffs like the old days. The only reason to go up in size is for additional expansion options.\r\n2U models allow for multiple "low-profile" PCI-Express cards while keeping a compact form factor and also providing some additional storage space. If the plan is to use multiple full height cards, then 3U or 4U servers should be the focus. The 4U models are very popular and offer flexible options. The 3U models do have limitations on expansion card compatibility and are really only for situations where rack space needs to be absolutely optimized (14x3U servers or 10x4U servers can fit in a 42u rack).","materialsDescription":"<span style=\"font-weight: bold;\">What is a ‘rack unit’?</span>\r\nA rack unit is the designated unit of measurement used when describing or quantifying the vertical space you have available in any equipment rack. One unit is equal to 1.75 inches, or 4.45 centimeters. Any equipment that has the ability to be mounted onto a rack is generally designed in a standard size to fit into many different server rack heights. It’s actually been standardized by the Electronic Industries Alliance (EIA). The most common heights are between 8U to 50U, but customization is also a viable option if you’re working with nonstandard sizes.\r\n<span style=\"font-weight: bold;\">Are there any specific ventilation requirements with server racks?</span>\r\nOver 65% of IT equipment failures are directly attributed to inadequate, poorly maintained, or failed air conditioning in the server room. So yes, proper ventilation is a critical part of maintaining any data center. Some cabinet manufacturers construct side panel ventilation instead of front and back ventilation, but experts say it’s inadequate for rack mount servers. This can be especially dangerous if more than one cabinet is being set up at once. The importance of proper ventilation should not be taken lightly, and you should always opt for front to back ventilation except in network applications where the IT equipment exhausts out the side.\r\n<span style=\"font-weight: bold;\">What is meant by ‘server rack depth’?</span>\r\nServer rack depth is a critical aspect of the ventilation process. Connectworld.net says, “Server cabinet depth is important not only because it has to allow room for the depth of the particular equipment to be rack-mounted (deep servers vs. routers or switches), but also it has to allow sufficient room for cables, PDU’s as well as airflow.<br /><br />","iconURL":"https://old.roi4cio.com/fileadmin/user_upload/icon_Rack_Server.png"}],"additionalInfo":{"budgetNotExceeded":"-1","functionallyTaskAssignment":"-1","projectWasPut":"-1","price":0,"source":{"url":"https://ko.com.ua/sportmaster_konsolidaciya_centralizaciya_virtualizaciya_79911","title":"Media"}},"comments":[],"referencesCount":0}},"aliases":{"1":["hp-3par-storeserv-hp-bladesystem-hp-bl-servers-to-software-developer-in-the-field-of-public-health","hp-bl-servers-and-hp-eva-storage-for-ibox","hp-bladesystem-and-hp-3par-for-the-operator-of-the-system-of-main-oil-pipelines-of-ukraine","bladesystem-c7000-hp-eva-hp-bl-servers-for-retail-allo-network","hp-bladesystem-for-steel-plant","hp-bladesystem-hp-eva-for-ukrainian-energy-company","hp-bladesystem-hp-procurve-hp-bl-servers-for-kovalskaya-plant","hp-proliant-bl-hp-eva-storage-hpe-bladesystem-c7000-oilfield-enclosures","hp-proliant-bl-hp-proliant-bl-hp-eva-for-ecomarket-chain","hpe-bladesystems-c7000-hp-eva-hp-proliant-bl-for-sportmaster-network"]},"links":{"first":"http://apis.roi4cio.com/api/implementations?page=1","last":"http://apis.roi4cio.com/api/implementations?page=1","prev":null,"next":null},"meta":{"current_page":1,"from":1,"last_page":1,"path":"http://apis.roi4cio.com/api/implementations","per_page":20,"to":10,"total":10},"loading":false,"error":null},"agreements":{"agreementById":{},"ids":{},"links":{},"meta":{},"loading":false,"error":null},"comparison":{"loading":false,"error":false,"templatesById":{},"comparisonByTemplateId":{},"products":[],"selectedTemplateId":null},"presentation":{"type":null,"company":{},"products":[],"partners":[],"formData":{},"dataLoading":false,"dataError":false,"loading":false,"error":false},"catalogsGlobal":{"subMenuItemTitle":""}}